17 410

Cited 0 times in

Efficiency of Ultrasonography and CT Angiography in Follow-up Studies of Carotid Stent and Percutaneous Transluminal Angioplasty

DC Field Value Language
dc.contributor.author안정용-
dc.date.accessioned2020-01-23T05:05:23Z-
dc.date.available2020-01-23T05:05:23Z-
dc.date.issued1999-
dc.identifier.issn0301-2867-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/173984-
dc.description.abstractPURPOSE: The aim of this study was to determine a more appropriate method for follow-up of carotid stenting by comparing the efficiency of US and CT angiography. MATERIALS AND METHODS: Eleven carotid arteries of seven patients(men: 5, women: 2, mean age: 56.4years) who underwent stent placement and percutaneous transluminal angioplasty(PTA) because of carotid stenosis were studied. The follow-up periods ranged from three to eleven(mean, five) months, and US and CT angiography were performed in one day. Color duplex sonography was performed with a 10 MHz linear array transducer. After spiral CT scan were obtained, MPR images were reconstructed on a workstation. Retrospective imaging analysis specifically focused on [1] stent configuration, [2] the accuracy of internal diameter measurement, [3] the detection of blood flow and the measurement of blood flow velocity, [4] the presence of atheroma and intraluminal thrombi, [5] the measurement of stent location, and [6] artifacts. RESULT: US was more accurate than CT angiography for measuring internal diameter. In all cases, US and CT angiography were able to detect the blood flow at carotid artery, and utilizing the Doppler spectrum, flow velocity was measured. US showed atheromas in all cases but CT angiography demonstrated calcified atheromas in three cases only. In six cases, US failed to determine stent location, though in this respect CT angiography was successful in all cases. Artifacts of US were small reverbe ration artifact(11/11) of the stent and a defective color Doppler signal caused by acoustic shadowing of atheroma calcification(3/11). Artifacts of CT angiogrpahy were hard-beam artifact of the stent(11/11) and motion artifact(3/11). CONCLUSION: US was superior to CT angiography in accuracy of measuring stent diameter, hemodynamic assessment, high-resolution views of the luminal state of the stent and minimal artifacts for the non-inva s i ve follow-up studies of carotid stenting.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageKorean-
dc.publisher대한방사선의학회-
dc.relation.isPartOfJournal of the Korean Radiologist Society (대한방사선의학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleEfficiency of Ultrasonography and CT Angiography in Follow-up Studies of Carotid Stent and Percutaneous Transluminal Angioplasty-
dc.title.alternative경동맥스텐트 삽입 후 추적검사로서의 초음파와 CT 혈관조영술의 유용성-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Neurosurgery (신경외과학교실)-
dc.contributor.googleauthorChang Woo Ryu-
dc.contributor.googleauthorByung Hee Lee-
dc.contributor.googleauthorBong Sub Chung-
dc.contributor.googleauthorJung Yong Ahn-
dc.contributor.googleauthorKyung Heo-
dc.contributor.googleauthorYoung Sik Kho-
dc.identifier.doi10.3348/jkrs.1999.41.6.1101-
dc.contributor.localIdA02260-
dc.relation.journalcodeJ01844-
dc.subject.keywordCarotid arteries-
dc.subject.keywordinterventional procedure-
dc.subject.keywordCarotid arteries-
dc.subject.keywordUS-
dc.contributor.alternativeNameAhn, Jung Yong-
dc.contributor.affiliatedAuthor안정용-
dc.citation.volume41-
dc.citation.number6-
dc.citation.startPage1101-
dc.citation.endPage1106-
dc.identifier.bibliographicCitationJournal of the Korean Radiologist Society (대한방사선의학회지), Vol.41(6) : 1101-1106, 1999-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.