229 475

Cited 23 times in

The validity of random urine specimen albumin measurement as a screening test for diabetic nephropathy

DC Field Value Language
dc.contributor.author김정호-
dc.contributor.author안철우-
dc.contributor.author이현철-
dc.contributor.author임승길-
dc.contributor.author최규헌-
dc.date.accessioned2019-11-26T01:03:19Z-
dc.date.available2019-11-26T01:03:19Z-
dc.date.issued1999-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/172697-
dc.description.abstractTo assess the validity of urine albumin concentration (UAC) and the urine albumin:creatine ratio (UACR) in a random urine specimen (RUS) for screening diabetic nephropathy in Korea, a total of 105 ambulatory diabetes mellitus patients (male:female, 52:53), ages 40-75 years (median 59 years) collected 105 RUSs after completing a timed 24 hour urine collection. Albumin was measured by immunonephelometry. According to the timed urinary albumin excretion rate (UAER) measured in the 24 hour collection (criterion standard), samples were classified normoalbuminuric (UAER < 20 micrograms/min; n = 50), microalbuminuric (UAER 20-200 micrograms/min; n = 30), and macroalbuminuric (UAER > 200 micrograms/min; n = 25). The receiver operating characteristics (ROC) curve of UAC and UACR in a RUS for screening of microalbuminuria (normo- and microalbuminuric samples; n = 80) and macroalbuminuria (micro- and macroalbuminuric samples; n = 55) were plotted. Pearson's coefficients of correlation of 24 hour UAER vs. UAC and UACR were 0.81 and 0.75, respectively (P < 0.001). The point of intersection with a 100%-to-100% diagonal for microalbuminuria were as follows: 31.0 mg/l for UAC and 32.5 mg/g for UACR; for macroalbuminuria 181 mg/l for UAC and 287.3 mg/g for UACR. The sensitivity and specificity of the cut-off points for microalbuminuria were 77% and 82% for UAC and 77% and 92% for UACR. The sensitivity and specificity of the cut-off points for macroalbuminuria were 84% and 90% for UAC and 88% and 90% for UACR. In present study, no difference was observed when comparing the performance of UAC and UACR based on a statistical comparison by McNemar test. The repeated measurements of UAC and UACR in the same individual were statistically similar and were correlated with each other. Based on these results, albumin measurements (UAC and UACR) in a RUS were considered as a valid test for screening diabetic nephropathy.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHAlbuminuria/diagnosis*-
dc.subject.MESHDiabetic Nephropathies/diagnosis*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.titleThe validity of random urine specimen albumin measurement as a screening test for diabetic nephropathy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학교실)-
dc.contributor.googleauthorChurl Woo Ahn-
dc.contributor.googleauthorYoung Duk Song-
dc.contributor.googleauthorJung Ho Kim-
dc.contributor.googleauthorSung Kil Lim-
dc.contributor.googleauthorKyu Hyun Choi-
dc.contributor.googleauthorKyung Rae Kim-
dc.contributor.googleauthorHyun Chul Lee-
dc.contributor.googleauthorKap Bum Huh-
dc.identifier.doi10.3349/ymj.1999.40.1.40-
dc.contributor.localIdA00903-
dc.contributor.localIdA02270-
dc.contributor.localIdA03301-
dc.contributor.localIdA03375-
dc.contributor.localIdA04043-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid10198605-
dc.contributor.alternativeNameKim, Jeong Ho-
dc.contributor.affiliatedAuthor김정호-
dc.contributor.affiliatedAuthor안철우-
dc.contributor.affiliatedAuthor이현철-
dc.contributor.affiliatedAuthor임승길-
dc.contributor.affiliatedAuthor최규헌-
dc.citation.volume40-
dc.citation.number1-
dc.citation.startPage40-
dc.citation.endPage45-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.40(1) : 40-45, 1999-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.