304 287

Cited 0 times in

담도배액관 유도 유도부 절개술-난해한 유두부주위 게실 및 위 부분절제술 환자에서-

Other Titles
 A Stent-Guided Sphincterotomy in Patients with a Difficult Periampullary Diverticulum or with a Billroth-II Gastrectomy 
Authors
 이동기  ;  김현수  ;  백순구  ;  정연수  ;  김광현  ;  권상옥 
Citation
 Korean Journal of Gastrointestinal Endoscopy (대한소화기내시경학회지), Vol.20(1) : 26-32, 2000 
Journal Title
Korean Journal of Gastrointestinal Endoscopy(대한소화기내시경학회지)
ISSN
 1225-7001 
Issue Date
2000
Keywords
Stent-guided sphincterotomy ; Billroth-II gastrectomy ; Periampullary diverticulum
Abstract
Background/Aims:
Patients with a congenitally or surgically altered anatomy such as a large diverticulum in which an ampullary orifice exists or a Billroth-II gastrectomy, have an increased complication rate after endoscopic sphincterotomy (EST) compared to normal anatomies. An experience involving a stent-guided sphincterotomy using an endoprosthesis is herein reported.
Methods:
10 patients with a Billroth-II gastrectomy and 9 patients with a large diverticulum received a stent-guided EST. In the diverticula cases, all the ampullary orifices were located either inside the diverticulum or in an unusual position. All patients had common bile duct stones and symptoms of cholangitis. After a 0.035 inch guide wire was inserted through the side-viewing duodenoscope, a 10 Fr. endoprosthesis (MTW, Germany) was inserted and a needle-knife sphincterotome was introduced. In patients with a Billroth-II anatomy, the incision was made from the papillary orifice of the 12 o'clock position toward 6 o'clock. In patients with periampullary diverticula, the incision was made with sweeps of the needle-knife in a 6 to 12 o'clock direction. The cautery current was applied to the mucosa along the stent and the stent was retrieved by a polypectomy snare through the biopsy channel without removal of an endoscope.
Results:
Among the 19 patients, the guide wire and stent insertion were possible in all except one patient due to the inability of selective cannulation. An EST was performed in all patients after stent insertion. There were no serious complications during and after the stent-guided EST except for two minor bleedings which were treated with a coagulation current using the needle-knife. Consequently, complete endoscopic stone removal was achieved in all patients including three patients in whom a mechanical lithotriptor was needed.
Conclusions:
In stent-guided EST, the stent not only guides the adequate direction of the incision but also allows a controlled incision under a favorable visual field. Therefore, blind cutting and exploration during EST can be avoided and successful EST is possible even in difficult situations such as that created by an altered anatomy. (Korean J Gastrointest Endosc 2000;20:26~32)
Files in This Item:
T200000755.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Lee, Dong Ki(이동기) ORCID logo https://orcid.org/0000-0002-0048-9112
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/172171
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links