239 349

Cited 0 times in

파형도관(corrugated tube)을 부착하여 사용할 때 Laerdal 소생낭이 전달하는 산소 농도의 변화

DC Field Value Language
dc.contributor.author고신옥-
dc.date.accessioned2019-11-11T05:40:03Z-
dc.date.available2019-11-11T05:40:03Z-
dc.date.issued2000-
dc.identifier.issn0302-5780-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/172060-
dc.description.abstractBackground : In emergency rooms or intensive care units, we have shown delivery of higher fractions of oxygen promptly for respiratory or cardiac arrest patients by using resuscitating instmments, especially the resuscitator bag. Previously we studied the variables affecting the fraction of delivered oxygen (FdOz) under varying ventilating techniques and conditions. In this paper, using corrugated tubes as substitute for reservoir bag, we measured FdOz and compared two. Methods : We designed a special wooden box, which held the Laerdal resuscitator bag. We measured the FdOz with or without reservoir bags and corrugated tubes at various tidal volumes, respiration rates and oxygen flows. Results : With a 500 ml corrugated tube, FdOz were higher than with a 250 ml corrugted tube but lower than with a reservoir bag. Conclusions : Corrugated tube is less effective to deliver high fractions of oxygen than the reservior bag, but it is acceptable to use corrugated tube as a substitute for a reservior bag than not to use it at all. (Korean J Anesthesiol 2000; 38: 327~332)-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한마취과학회-
dc.relation.isPartOfJournal of Korean Society of Anesthesiologist (대한마취과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title파형도관(corrugated tube)을 부착하여 사용할 때 Laerdal 소생낭이 전달하는 산소 농도의 변화-
dc.title.alternativeThe changes in delivered oxygen fraction using LAerdal resuscitatorr bag-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine (마취통증의학교실)-
dc.contributor.googleauthor김기준-
dc.contributor.googleauthor남용택-
dc.contributor.googleauthor구민우-
dc.contributor.googleauthor전성식-
dc.contributor.googleauthor고신옥-
dc.identifier.doi10.4097/kjae.2000.38.2.327-
dc.contributor.localIdA00126-
dc.relation.journalcodeJ01540-
dc.subject.keywordOxygen-
dc.subject.keyworddelibery system-
dc.subject.keywordfraction-
dc.subject.keywordVentilation-
dc.subject.keywordCorrugated tube-
dc.subject.keywordlaerdal resuscitator bag-
dc.subject.keywordreservoir bag-
dc.contributor.alternativeNameKoh, Shin Ok-
dc.contributor.affiliatedAuthor고신옥-
dc.citation.volume38-
dc.citation.number2-
dc.citation.startPage327-
dc.citation.endPage332-
dc.identifier.bibliographicCitationJournal of Korean Society of Anesthesiologist (대한마취과학회지), Vol.38(2) : 327-332, 2000-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.