승모판 협착증에서 하모닉 영상을 이용한 좌심방내 자발성 에코 영상의 관찰

DC Field Value Language
dc.contributor.author강석민-
dc.contributor.author임세중-
dc.contributor.author정남식-
dc.contributor.author하종원-
dc.date.accessioned2019-11-11T05:17:56Z-
dc.date.available2019-11-11T05:17:56Z-
dc.date.issued2000-
dc.identifier.issn1738-5520-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/171766-
dc.description.abstractBackground: Spontaneous echo contrast (SEC) of the left atrium (LA) is associated with increased risk of thromboembolism in patients with mitral stenosis(MS). The determination of the presence and severity of LA spontaneous echo contrast (SEC) is of prognostic importance in these patients. Harmonic imaging(HI), a novel echocardiographic technique that differs from conventional fundamental imaging (FI) by transmitting ultrasound at one frequency and receiving at twice the transmitted frequency, produces better endocardial border definition and myocardial opacification. However, there are no data about its value on the detection of LA SEC. The purpose of this study was to investigate the utility of transthoracic noncontrast HI in the detection of LA SEC in patients with MS. Methods: Seventy-four consecutive patients with MS (49 female, mean age 51) underwent standard transthoracic echocardiograms (TTE) in both HI and FI and transesophageal echocardiography (TEE) to determine the presence and severity of LA SEC. LA SEC was graded by TEE ; mild if only seen at high gain, severe if visible in the entire LA at normal gain control of the equipment. Control subjects comprised of 30 patients randomly selected from patients who did not have LA SEC at TEE examination. Results: Atrial fibrillation was found in 46 patients (62.2%). The mean mitral valve area and mean mitral gradient were 1.0±0.3 ㎠ and 8.2±4.1㎜Hg, respectively. Nine patients (12.2%) had episodes of systemic embolism ; stroke in 8 and peripheral embolism in 1. LA thrombus was found in 11 patients (14.9%) by TEE. LA SEC was present in all but one patient by TEE (mild in 35, severe in 38 patients). FI of TTE, however, revealed LA SEC in only 5 (6.8%) of the 73 patients. In contrast, in HI, LA SEC could be detected in 63 (86.3%) of the 73 patients. In the detection of severe LA SEC, the sensitivity of FI and HI were 13.2% (5/38) and 100% (38/38), respectively. LA SEC was not observed in control subjects either by FI or HI. Conclusion: Transthoracic HI significantly enhances the detection of LA SEC in patients with MS.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish, Korean-
dc.publisherKorean Society of Circulation-
dc.relation.isPartOfKorean Circulation Journal-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title승모판 협착증에서 하모닉 영상을 이용한 좌심방내 자발성 에코 영상의 관찰-
dc.title.alternativeEnhanced Detection of Left Atrial Spontaneous Echo Contrast by Transthoracic Harmonic Imaging in Mitral Stenosis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthor하종원-
dc.contributor.googleauthor강석민-
dc.contributor.googleauthor장길진-
dc.contributor.googleauthor김인제-
dc.contributor.googleauthor김지영-
dc.contributor.googleauthor황은경-
dc.contributor.googleauthor김현주-
dc.contributor.googleauthor임세중-
dc.contributor.googleauthor정남식-
dc.contributor.localIdA00037-
dc.contributor.localIdA03372-
dc.contributor.localIdA03585-
dc.contributor.localIdA04257-
dc.relation.journalcodeJ01952-
dc.identifier.eissn1738-5555-
dc.subject.keyword하모닉 영상-
dc.subject.keyword좌심방내 자발 에코 영상-
dc.subject.keyword승모판 협착증-
dc.contributor.alternativeNameKang, Seok Min-
dc.contributor.affiliatedAuthor강석민-
dc.contributor.affiliatedAuthor임세중-
dc.contributor.affiliatedAuthor정남식-
dc.contributor.affiliatedAuthor하종원-
dc.citation.volume30-
dc.citation.number10-
dc.citation.startPage1230-
dc.citation.endPage1237-
dc.identifier.bibliographicCitationKorean Circulation Journal, Vol.30(10) : 1230-1237, 2000-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.