Cited 5 times in
Comparison of clinical outcomes of two different types of paclitaxel-coated balloons for treatment of patients with coronary in-stent restenosis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 고영국 | - |
dc.contributor.author | 김병극 | - |
dc.contributor.author | 김중선 | - |
dc.contributor.author | 김충기 | - |
dc.contributor.author | 안철민 | - |
dc.contributor.author | 장양수 | - |
dc.contributor.author | 최동훈 | - |
dc.contributor.author | 홍명기 | - |
dc.contributor.author | 홍성진 | - |
dc.date.accessioned | 2019-10-28T01:30:27Z | - |
dc.date.available | 2019-10-28T01:30:27Z | - |
dc.date.issued | 2019 | - |
dc.identifier.issn | 0910-8327 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/171230 | - |
dc.description.abstract | Drug-coated balloon (DCB) angioplasty has been shown to be a promising option for the treatment of coronary in-stent restenosis (ISR). We compared the clinical outcomes of patients with ISR who were treated with two commonly used paclitaxel-containing DCBs, the Pantera Lux (PL) and SeQuent Please (SP). A total of 491 patients with 507 ISR lesions [PL-DCB in 127 (26%) patients and SP-DCB in 364 (74%) patients] underwent DCB angioplasty for ISR lesions. The major adverse cardiac events (MACEs), including cardiac death, target lesion-related myocardial infarction, and target lesion revascularization, were assessed. There were no significant differences in each occurrence of MACE and cardiac death: 16 MACEs (61 per 1000 person-years) in the PL-DCB group and 55 (60 per 1000 person-years) MACEs in the SP-DCB group, log-rank p = 0.895, and three cardiac deaths (11 per 1000 person-years) in the PL-DCB group and ten cardiac deaths (11 per 1000 person-years) in the SP-DCB group, log-rank p = 0.849. Diabetes mellitus under insulin treatment [hazard ratio (HR) 2.71; 95% confidence interval (CI) 1.31-5.60; p = 0.007], chronic kidney disease (HR 1.99; 95% CI 1.01-3.92; p = 0.045), early-onset ISR (HR 1.99; 95% CI 1.18-3.36; p = 0.010), and recurrent ISR (HR 1.89; 95% CI 1.08-3.32; p = 0.026) were associated with the occurrence of MACE after DCB angioplasty. There was no significant difference of MACE between PL-DCB and SP-DCB treatment in patients with ISR. Patients with insulin-treated diabetes, chronic kidney disease, early-onset ISR, and recurrent ISR were at a higher risk of MACE after DCB angioplasty. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Springer Verlag | - |
dc.relation.isPartOf | Heart and Vessels | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Comparison of clinical outcomes of two different types of paclitaxel-coated balloons for treatment of patients with coronary in-stent restenosis | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학교실) | - |
dc.contributor.googleauthor | Viet Phuong Thuy Nguyen | - |
dc.contributor.googleauthor | Choongki Kim | - |
dc.contributor.googleauthor | Sung-Jin Hong | - |
dc.contributor.googleauthor | Chul-Min Ahn | - |
dc.contributor.googleauthor | Jung-Sun Kim | - |
dc.contributor.googleauthor | Byeong-Keuk Kim | - |
dc.contributor.googleauthor | Young-Guk Ko | - |
dc.contributor.googleauthor | Donghoon Choi | - |
dc.contributor.googleauthor | Yangsoo Jang | - |
dc.contributor.googleauthor | Myeong-Ki Hong | - |
dc.identifier.doi | 10.1007/s00380-019-01388-z | - |
dc.contributor.localId | A00127 | - |
dc.contributor.localId | A00493 | - |
dc.contributor.localId | A00961 | - |
dc.contributor.localId | A01061 | - |
dc.contributor.localId | A02269 | - |
dc.contributor.localId | A03448 | - |
dc.contributor.localId | A04053 | - |
dc.contributor.localId | A04391 | - |
dc.contributor.localId | A04403 | - |
dc.relation.journalcode | J00978 | - |
dc.identifier.eissn | 1615-2573 | - |
dc.identifier.pmid | 30903315 | - |
dc.identifier.url | https://link.springer.com/article/10.1007%2Fs00380-019-01388-z | - |
dc.subject.keyword | Coronary artery disease | - |
dc.subject.keyword | Drug-coated balloon | - |
dc.subject.keyword | In-stent restenosis | - |
dc.contributor.alternativeName | Ko, Young Guk | - |
dc.contributor.affiliatedAuthor | 고영국 | - |
dc.contributor.affiliatedAuthor | 김병극 | - |
dc.contributor.affiliatedAuthor | 김중선 | - |
dc.contributor.affiliatedAuthor | 김충기 | - |
dc.contributor.affiliatedAuthor | 안철민 | - |
dc.contributor.affiliatedAuthor | 장양수 | - |
dc.contributor.affiliatedAuthor | 최동훈 | - |
dc.contributor.affiliatedAuthor | 홍명기 | - |
dc.contributor.affiliatedAuthor | 홍성진 | - |
dc.citation.volume | 34 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 1420 | - |
dc.citation.endPage | 1428 | - |
dc.identifier.bibliographicCitation | Heart and Vessels, Vol.34(9) : 1420-1428, 2019 | - |
dc.identifier.rimsid | 63853 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.