Cited 50 times in
Automatic evaluation of fetal head biometry from ultrasound images using machine learning
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 권자영 | - |
dc.contributor.author | 박예진 | - |
dc.date.accessioned | 2019-09-20T07:47:47Z | - |
dc.date.available | 2019-09-20T07:47:47Z | - |
dc.date.issued | 2019 | - |
dc.identifier.issn | 0967-3334 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/171057 | - |
dc.description.abstract | OBJECTIVE: Ultrasound-based fetal biometric measurements, such as head circumference (HC) and biparietal diameter (BPD), are frequently used to evaluate gestational age and diagnose fetal central nervous system pathology. Because manual measurements are operator-dependent and time-consuming, much research is being actively conducted on automated methods. However, the existing automated methods are still not satisfactory in terms of accuracy and reliability, owing to difficulties dealing with various artefacts in ultrasound images. APPROACH: Using the proposed method, a labeled dataset containing 102 ultrasound images was used for training, and validation was performed with 70 ultrasound images. MAIN RESULTS: A success rate of 91.43% and 100% for HC and BPD estimations, respectively, and an accuracy of 87.14% for the plane acceptance check. SIGNIFICANCE: This paper focuses on fetal head biometry and proposes a deep-learning-based method for estimating HC and BPD with a high degree of accuracy and reliability. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | IOP Pub. Ltd. | - |
dc.relation.isPartOf | Physiological Measurement | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.title | Automatic evaluation of fetal head biometry from ultrasound images using machine learning | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Obstetrics and Gynecology (산부인과학교실) | - |
dc.contributor.googleauthor | Hwa Pyung Kim | - |
dc.contributor.googleauthor | Sung Min Lee | - |
dc.contributor.googleauthor | Ja-Young Kwon | - |
dc.contributor.googleauthor | Yejin Park | - |
dc.contributor.googleauthor | Kang Cheol Kim | - |
dc.contributor.googleauthor | Jin Keun Seo | - |
dc.identifier.doi | 10.1088/1361-6579/ab21ac | - |
dc.contributor.localId | A00246 | - |
dc.contributor.localId | A04836 | - |
dc.relation.journalcode | J02527 | - |
dc.identifier.eissn | 1361-6579 | - |
dc.identifier.pmid | 31091515 | - |
dc.identifier.url | https://iopscience.iop.org/article/10.1088/1361-6579/ab21ac | - |
dc.contributor.alternativeName | Kwon, Ja Young | - |
dc.contributor.affiliatedAuthor | 권자영 | - |
dc.contributor.affiliatedAuthor | 박예진 | - |
dc.citation.volume | 40 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 65009 | - |
dc.identifier.bibliographicCitation | Physiological Measurement, Vol.40(6) : 65009, 2019 | - |
dc.identifier.rimsid | 63347 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.