423 704

Cited 0 times in

Skin Dose Comparison of CyberKnife and Helical Tomotherapy for Head-and-Neck Stereotactic Body Radiotherapy

DC Field Value Language
dc.contributor.author김용배-
dc.contributor.author김진성-
dc.contributor.author박광우-
dc.contributor.author이호-
dc.date.accessioned2019-07-11T03:33:14Z-
dc.date.available2019-07-11T03:33:14Z-
dc.date.issued2019-
dc.identifier.issn1226-5829-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/170032-
dc.description.abstractPurpose: This study conducts a comparative evaluation of the skin dose in CyberKnife (CK) and Helical Tomotherapy (HT) to predict the accurate dose of radiation and minimize skin burns in headand- neck stereotactic body radiotherapy. Materials and Methods: Arbitrarily-defined planning target volume (PTV) close to the skin was drawn on the planning computed tomography acquired from a head-and-neck phantom with 19 optically stimulated luminescent dosimeters (OSLDs) attached to the surface (3 OSLDs were positioned at the skin close to PTV and 16 OSLDs were near sideburns and forehead, away from PTV). The calculation doses were obtained from the MultiPlan 5.1.2 treatment planning system using raytracing (RT), finite size pencil beam (FSPB), and Monte Carlo (MC) algorithms for CK. For HT, t he s kin d ose w as e stimated v ia c onvolution s uperposition ( CS) a lgorithm f rom t he Tomotherapy planning station 5.0.2.5. The prescribed dose was 8 Gy for 95% coverage of the PTV. Results and Conclusions: The mean differences between calculation and measurement values were −1.2±3.1%, 2.5±7.9%, −2.8±3.8%, −6.6±8.8%, and −1.4±1.8% in CS, RT, RT with contour correction (CC), FSPB, and MC, respectively. FSPB showed a dose error comparable to RT. CS and RT with CC led to a small error as compared to FSPB and RT. Considering OSLDs close to PTV, MC minimized the uncertainty of skin dose as compared to other algorithms.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageKorean, English-
dc.publisher한국의학물리학회-
dc.relation.isPartOfKorean Journal of Medical Physics (의학물리)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleSkin Dose Comparison of CyberKnife and Helical Tomotherapy for Head-and-Neck Stereotactic Body Radiotherapy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학교실)-
dc.contributor.googleauthorJeongmin Yoon-
dc.contributor.googleauthorKwangwoo Park-
dc.contributor.googleauthorJin Sung Kim-
dc.contributor.googleauthorYong Bae Kim-
dc.contributor.googleauthorHo Lee-
dc.identifier.doi10.14316/pmp.2019.30.1.1-
dc.contributor.localIdA00744-
dc.contributor.localIdA04548-
dc.contributor.localIdA01432-
dc.contributor.localIdA03323-
dc.relation.journalcodeJ02057-
dc.identifier.eissn2288-9620-
dc.subject.keywordCyberKnife-
dc.subject.keywordSkin dose-
dc.subject.keywordHelical TomoTherapy-
dc.subject.keywordSBRT-
dc.contributor.alternativeNameKim, Yong Bae-
dc.contributor.affiliatedAuthor김용배-
dc.contributor.affiliatedAuthor김진성-
dc.contributor.affiliatedAuthor박광우-
dc.contributor.affiliatedAuthor이호-
dc.citation.volume30-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage6-
dc.identifier.bibliographicCitationKorean Journal of Medical Physics (의학물리), Vol.30(1) : 1-6, 2019-
dc.identifier.rimsid63042-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.