578 611

Cited 7 times in

A Newly-Developed Flow Diverter (FloWise) for Internal Carotid Artery Aneurysm: Results of a Pilot Clinical Study

DC Field Value Language
dc.contributor.author이재환-
dc.contributor.author정준호-
dc.date.accessioned2019-05-29T05:18:46Z-
dc.date.available2019-05-29T05:18:46Z-
dc.date.issued2019-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/169523-
dc.description.abstractOBJECTIVE: We report the results of a pilot clinical study that evaluated the safety and efficacy of a newly-developed, retrievable flow diverter (FloWise; Taewoong Medical) for the treatment of internal carotid artery (ICA) aneurysm. MATERIALS AND METHODS: A total of 10 patients were enrolled. Inclusion criteria were 1) unruptured aneurysm with a dome size of ≥ 8 mm and a neck size of ≥ 4 mm at the ICA, or 2) two or more unruptured aneurysms of any size able to be spanned by a single FloWise at the ICA. Co-primary effectiveness end points were technical success of FloWise placement, and a 50% or greater decrease in aneurysm volume at the 6-month follow-up angiogram. The primary safety end point was the new development of neurological deficits persisting for more than 1-month post-treatment. RESULTS: Ten patients harboring 14 ICA aneurysms (median diameter, 9.4 mm; range, 2.3-31.0 mm) were enrolled between January 2016 and July 2017. FloWise placement was successful in all patients. There were no newly-developed neurological deficits during the 6-month clinical follow-up period. One patient did not receive follow-up imaging due to pregnancy. Nine patients with 12 aneurysms received a 6-month angiographic follow-up. Ten aneurysms (83.3%) showed decreases in volume greater than 50% (mean volume decrease, 82.8 ± 32.9%), of which 8 (66.7%, 95% confidence interval, 35.4-98.0%) showed complete occlusion. One patient was retreated due to mass symptom aggravation. CONCLUSIONS: In this pilot study, FloWise appeared to be safe and effective for ICA aneurysm treatment. A prospective multicenter study to validate the effectiveness and safety of FloWise would be worthwhile.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKorean Society of Radiology-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleA Newly-Developed Flow Diverter (FloWise) for Internal Carotid Artery Aneurysm: Results of a Pilot Clinical Study-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Neurosurgery (신경외과학교실)-
dc.contributor.googleauthorByung Moon Kim-
dc.contributor.googleauthorKeun Young Park-
dc.contributor.googleauthorJae Whan Lee-
dc.contributor.googleauthorJoonho Chung-
dc.contributor.googleauthorDong Joon Kim-
dc.contributor.googleauthorDong Ik Kim-
dc.identifier.doi10.3348/kjr.2018.0421-
dc.contributor.localIdA03088-
dc.contributor.localIdA03731-
dc.relation.journalcodeJ02884-
dc.identifier.eissn2005-8330-
dc.identifier.pmid30799582-
dc.subject.keywordFlow diversion-
dc.subject.keywordIntracranial aneurysm-
dc.subject.keywordNew device-
dc.contributor.alternativeNameLee, Jae Whan-
dc.contributor.affiliatedAuthor이재환-
dc.contributor.affiliatedAuthor정준호-
dc.citation.volume20-
dc.citation.number3-
dc.citation.startPage505-
dc.citation.endPage512-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, Vol.20(3) : 505-512, 2019-
dc.identifier.rimsid62585-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.