326 733

Cited 6 times in

Left Ventricular End-Systolic Volume Can Predict 1-Year Hierarchical Clinical Composite End Point in Patients with Cardiac Resynchronization Therapy

DC Field Value Language
dc.contributor.author강석민-
dc.contributor.author김인수-
dc.contributor.author김태훈-
dc.contributor.author박희남-
dc.contributor.author엄재선-
dc.contributor.author오재원-
dc.contributor.author유희태-
dc.contributor.author이문형-
dc.contributor.author정보영-
dc.contributor.author조인정-
dc.contributor.author진무년-
dc.contributor.author김태훈-
dc.date.accessioned2019-02-14T01:57:26Z-
dc.date.available2019-02-14T01:57:26Z-
dc.date.issued2019-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/167314-
dc.description.abstractPURPOSE: This study aimed to elucidate which echocardiographic criteria at three time points, for cardiac resynchronization therapy (CRT) response, are accurate in discriminating the hierarchical clinical composite end point (HCCEP). MATERIALS AND METHODS: We included 120 patients (age, 66.1±12.6 years; men, 54.2%) who underwent CRT implantation for heart failure (HF). Echocardiography was performed before and at 3, 6, and 12 months after CRT implantation. The 1-year HCCEP included all-cause mortality, hospitalization for HF, and New York Heart Association functional class for 12 months. CRT response criteria were decrease in left ventricular (LV) end-systolic volume (LVESV) >15%, decrease in LV end-diastolic volume >15%, absolute increase in LV ejection fraction (LVEF) ≥5%, relative increase in LVEF ≥15%, and decrease in mitral regurgitation ≥1 grade. Temporal changes in CRT response rates, accuracy of CRT response criteria at each time and cutoff value for the discrimination of improvement in HCCEP, and agreements with improvement in HCCEP were analyzed. RESULTS: HCCEP improvement rates were 65.8% in total group. In nonischemic group, CRT response rates according to all echocardiographic criteria significantly increased with time. In ischemic group, CRT response rate did not significantly change with time. In total group, ΔLVESV at 6 months (ΔLVESV6) had the most significant accuracy for the discrimination of HCCEP (area under the curve=0.781). The optimal cutoff value of ΔLVESV6 was 13.5% (sensitivity=0.719, specificity=0.719). ΔLVESV6 had fair agreement with HCCEP (κ=0.391, p<0.001). CONCLUSION: ΔLVESV6 is the most useful echocardiographic CRT response criterion for the prediction of 1-year HCCEP.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHCardiac Resynchronization Therapy*-
dc.subject.MESHEchocardiography-
dc.subject.MESHEndpoint Determination*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHROC Curve-
dc.subject.MESHStroke Volume*-
dc.subject.MESHTime Factors-
dc.subject.MESHTreatment Outcome-
dc.titleLeft Ventricular End-Systolic Volume Can Predict 1-Year Hierarchical Clinical Composite End Point in Patients with Cardiac Resynchronization Therapy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthorJae-Sun Uhm-
dc.contributor.googleauthorJaewon Oh-
dc.contributor.googleauthorIn-Jeong Cho-
dc.contributor.googleauthorMinsu Park-
dc.contributor.googleauthorIn-Soo Kim-
dc.contributor.googleauthorMoo-Nyun Jin-
dc.contributor.googleauthorHan Joon Bae-
dc.contributor.googleauthorHee Tae Yu-
dc.contributor.googleauthorTae-Hoon Kim-
dc.contributor.googleauthorHui-Nam Pak-
dc.contributor.googleauthorMoon-Hyoung Lee-
dc.contributor.googleauthorBoyoung Joung-
dc.contributor.googleauthorSeok-Min Kang-
dc.identifier.doi10.3349/ymj.2019.60.1.48-
dc.contributor.localIdA00037-
dc.contributor.localIdA00840-
dc.contributor.localIdA05466-
dc.contributor.localIdA01776-
dc.contributor.localIdA02337-
dc.contributor.localIdA02395-
dc.contributor.localIdA02535-
dc.contributor.localIdA02766-
dc.contributor.localIdA03609-
dc.contributor.localIdA03892-
dc.contributor.localIdA03980-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid30554490-
dc.subject.keywordCardiac resynchronization therapy-
dc.subject.keywordechocardiography-
dc.subject.keywordheart failure-
dc.contributor.alternativeNameKang, Seok Min-
dc.contributor.affiliatedAuthor강석민-
dc.contributor.affiliatedAuthor김인수-
dc.contributor.affiliatedAuthor김태훈-
dc.contributor.affiliatedAuthor박희남-
dc.contributor.affiliatedAuthor엄재선-
dc.contributor.affiliatedAuthor오재원-
dc.contributor.affiliatedAuthor유희태-
dc.contributor.affiliatedAuthor이문형-
dc.contributor.affiliatedAuthor정보영-
dc.contributor.affiliatedAuthor조인정-
dc.contributor.affiliatedAuthor진무년-
dc.citation.volume60-
dc.citation.number1-
dc.citation.startPage48-
dc.citation.endPage55-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.60(1) : 48-55, 2019-
dc.identifier.rimsid61516-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.