0 639

Cited 2 times in

Effects of bismuth breast shielding on iodine quantification in dual-energy computed tomography: an experimental phantom study

DC Field Value Language
dc.contributor.author김영진-
dc.contributor.author이혜정-
dc.contributor.author임동진-
dc.contributor.author최병욱-
dc.contributor.author허진-
dc.contributor.author홍유진-
dc.date.accessioned2019-02-12T16:45:29Z-
dc.date.available2019-02-12T16:45:29Z-
dc.date.issued2018-
dc.identifier.issn0284-1851-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/167127-
dc.description.abstractBACKGROUND: Although the bismuth breast shield can reduce radiation exposure to the breast during dual-energy computed tomography (DECT), it can potentially affect material quantification on DECT due to artifacts. PURPOSE: To evaluate the effects of bismuth breast shielding on iodine quantification and radiation exposure in DECT. MATERIAL AND METHODS: Small balloons were made with 0.2%, 0.6% and 1.0% blended iodinated contrast (370 mg/mL of iodine) with water. The balloons were located at both anterior and posterior lungs in an adult anthropomorphic chest phantom. DECT was performed with and without breast shielding. Afterwards, iodine concentration values were measured for each balloon on the iodine maps. Absorbed radiation doses in the breast were measured with the optically stimulated luminescence dosimeter. RESULTS: After shielding, we obtained significantly decreased iodine quantification for all three concentrations with 0.78 ± 0.13 to 0.46 ± 0.13 mg/mL, 2.31 ± 0.17 to 1.68 ± 0.19 mg/mL, and 3.82 ± 0.10 to 2.84 ± 0.20 mg/mL at the anterior location, and 0.72 ± 0.11 to 0.48 ± 0.09 mg/mL, 2.24 ± 0.13 to 1.87 ± 0.21 mg/mL, and 3.75 ± 0.16 to 3.15 ± 0.14 mg/mL at the posterior location for the 0.2%, 0.6%, and 1.0% balloons, respectively ( P = 0.001 for all). After shielding, absorbed radiation doses to the breast significantly decreased by 14.8% (4.32 ± 0.33 to 3.68 ± 0.30 mGy; P = 0.005). CONCLUSION: Although using the bismuth breast shield may decrease radiation exposure to the breast on DECT, it may also significantly affect iodine quantification.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSage-
dc.relation.isPartOfACTA RADIOLOGICA-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleEffects of bismuth breast shielding on iodine quantification in dual-energy computed tomography: an experimental phantom study-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학교실)-
dc.contributor.googleauthorHyunsik Jang-
dc.contributor.googleauthorJin Hur-
dc.contributor.googleauthorByoung Wook Choi-
dc.contributor.googleauthorDong Jin Im-
dc.contributor.googleauthorYoo Jin Hong-
dc.contributor.googleauthorYoung Jin Kim-
dc.contributor.googleauthorHye-Jeong Lee-
dc.identifier.doi10.1177/0284185118768098-
dc.contributor.localIdA00727-
dc.contributor.localIdA03320-
dc.contributor.localIdA03361-
dc.contributor.localIdA04059-
dc.contributor.localIdA04370-
dc.contributor.localIdA04422-
dc.relation.journalcodeJ00033-
dc.identifier.eissn1600-0455-
dc.identifier.pmid29635925-
dc.identifier.urlhttps://journals.sagepub.com/doi/full/10.1177/0284185118768098-
dc.subject.keywordBismuth-
dc.subject.keyworddual-energy computed tomography-
dc.subject.keywordiodine-
dc.subject.keywordradiation dosage-
dc.subject.keywordradiation protection-
dc.contributor.alternativeNameKim, Young Jin-
dc.contributor.affiliatedAuthor김영진-
dc.contributor.affiliatedAuthor이혜정-
dc.contributor.affiliatedAuthor임동진-
dc.contributor.affiliatedAuthor최병욱-
dc.contributor.affiliatedAuthor허진-
dc.contributor.affiliatedAuthor홍유진-
dc.citation.volume59-
dc.citation.number12-
dc.citation.startPage1475-
dc.citation.endPage1481-
dc.identifier.bibliographicCitationACTA RADIOLOGICA, Vol.59(12) : 1475-1481, 2018-
dc.identifier.rimsid58107-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.