Cited 32 times in

Indoor air quality of daycare centers in Seoul, Korea

DC Field Value Language
dc.contributor.author박화미-
dc.date.accessioned2018-12-19T16:40:38Z-
dc.date.available2018-12-19T16:40:38Z-
dc.date.issued2017-
dc.identifier.issn0360-1323-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/166207-
dc.description.abstractWe determined the relation between indoor pollutants and certain building and environmental factors. We gathered data on variables such as biological pollutants (mold and bacteria), and chemical pollutants (formaldehyde, CO2, CO, and total volatile organic compounds, also known as TVOCs) from 25 daycare centers. The level of bacteria exceeded the limit of 800 CFU m−3 as mandated by Korea's Indoor Air Quality (IAQ) standard. The level of these bacteria showed a significant positive association with the building age and area, and a negative link with the ventilation time. As determined through a thermal assessment (p = 0.035), the levels of mold were significantly higher in water-damaged facilities than in those without. The levels of the five VOCs (benzene, toluene, ethylbenzene, xylene, and styrene) were observed at the highest indoors at night, compared to indoors and outdoors during the day. Proper ventilation and management of water and/or relative humidity in daycare buildings can help reduce the exposure to certain biological and chemical pollutants. The findings are useful to ensure the well-being of children in daycare centers.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherElsevier Science-
dc.relation.isPartOfBUILDING AND ENVIRONMENT-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleIndoor air quality of daycare centers in Seoul, Korea-
dc.typeArticle-
dc.contributor.collegeGraduate School of Public Health (보건대학원)-
dc.contributor.departmentGraduate School of Public Health (보건대학원)-
dc.contributor.googleauthorSung Ho Hwang-
dc.contributor.googleauthorSungChul Seo-
dc.contributor.googleauthorYoung Yoo-
dc.contributor.googleauthorKi Yeon Kim-
dc.contributor.googleauthorJi Tae Choung-
dc.contributor.googleauthorWha Me Park-
dc.identifier.doi10.1016/j.buildenv.2017.07.042-
dc.contributor.localIdA05569-
dc.relation.journalcodeJ03552-
dc.identifier.eissn1873-684X-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0360132317303414-
dc.subject.keywordDaycare centers-
dc.subject.keywordIndoor air quality-
dc.subject.keywordVentilation-
dc.subject.keywordBuilding characteristics-
dc.subject.keywordWater damage-
dc.subject.keywordManagement-
dc.contributor.alternativeNamePark, Wha Me-
dc.contributor.affiliatedAuthor박화미-
dc.citation.volume124-
dc.citation.startPage186-
dc.citation.endPage193-
dc.identifier.bibliographicCitationBUILDING AND ENVIRONMENT, Vol.124 : 186-193, 2017-
dc.identifier.rimsid59323-
dc.type.rimsART-
Appears in Collections:
4. Graduate School of Public Health (보건대학원) > Graduate School of Public Health (보건대학원) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.