Different Neointimal Pattern in Early vs. Late In-Stent Restenosis and Clinical Outcomes After Drug-Coated Balloon Angioplasty - An Optical Coherence Tomography Study.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 고영국 | - |
dc.contributor.author | 김병극 | - |
dc.contributor.author | 김중선 | - |
dc.contributor.author | 안철민 | - |
dc.contributor.author | 장양수 | - |
dc.contributor.author | 최동훈 | - |
dc.contributor.author | 홍명기 | - |
dc.contributor.author | 홍성진 | - |
dc.date.accessioned | 2018-11-16T17:00:41Z | - |
dc.date.available | 2018-11-16T17:00:41Z | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 1346-9843 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/165570 | - |
dc.description.abstract | BACKGROUND: There are few data of clinical outcomes after drug-coated balloon (DCB) angioplasty according to neointimal characteristics. This study investigated long-term clinical outcomes according to timing of in-stent restenosis (ISR) and neointimal characteristics in patients with drug-eluting stent (DES) ISR after DCB angioplasty. Methods and Results: In all, 122 patients (122 ISR lesions), treated with DCB under optical coherence tomography (OCT) examination before and after DCB, were categorized as early ISR (<12 months; E-ISR; n=21) and late ISR (≥12 months; L-ISR; n=101). Associations between OCT-based neointima characteristics and period of ISR, as well as clinical outcomes after DCB were evaluated. Major adverse cardiac events (MACE) were a composite of cardiac death, non-fatal myocardial infarction, or target lesion revascularization (TLR). Quantitative parameters of the neointima were similar, but qualitative characteristics showed significant differences between the E-ISR and L-ISR groups. The incidence of MACE (33.3% vs. 20.8%; P=0.069) and TLR (33.3% vs. 18.5%; P=0.040) was higher in the E-ISR group. In addition, the incidence of MACE was significantly higher for heterogeneous than non-heterogeneous neointima (43.7% vs. 19.6%; P=0.018), but was not significantly associated with neoatherosclerosis (33.4% vs. 18.4%; P=0.168). CONCLUSIONS: DCB angioplasty is less effective for heterogeneous neointima in DES ISR. OCT-based neointimal evaluation may be helpful in guiding treatment of DES ISR. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | English, Japanese | - |
dc.publisher | Japanese Circulation Society | - |
dc.relation.isPartOf | CIRCULATION JOURNAL | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Different Neointimal Pattern in Early vs. Late In-Stent Restenosis and Clinical Outcomes After Drug-Coated Balloon Angioplasty - An Optical Coherence Tomography Study. | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학교실) | - |
dc.contributor.googleauthor | Jung-Hee Lee | - |
dc.contributor.googleauthor | Hae Won Jung | - |
dc.contributor.googleauthor | Jung-Sun Kim | - |
dc.contributor.googleauthor | Sung-Jin Hong | - |
dc.contributor.googleauthor | Chul-Min Ahn | - |
dc.contributor.googleauthor | Byeong-Keuk Kim | - |
dc.contributor.googleauthor | Young-Guk Ko | - |
dc.contributor.googleauthor | Donghoon Choi | - |
dc.contributor.googleauthor | Myeong-Ki Hong | - |
dc.contributor.googleauthor | Yangsoo Jang | - |
dc.identifier.doi | 10.1253/circj.CJ-18-0619 | - |
dc.contributor.localId | A00127 | - |
dc.contributor.localId | A00493 | - |
dc.contributor.localId | A00961 | - |
dc.contributor.localId | A02269 | - |
dc.contributor.localId | A03448 | - |
dc.contributor.localId | A04053 | - |
dc.contributor.localId | A04391 | - |
dc.contributor.localId | A04403 | - |
dc.relation.journalcode | J00534 | - |
dc.identifier.eissn | 1347-4820 | - |
dc.identifier.pmid | 30197402 | - |
dc.subject.keyword | Drug-eluting balloon | - |
dc.subject.keyword | In-stent restenosis | - |
dc.subject.keyword | Optical coherence tomography | - |
dc.contributor.alternativeName | Ko, Young Guk | - |
dc.contributor.alternativeName | Kim, Byeong Keuk | - |
dc.contributor.alternativeName | Kim, Jung Sun | - |
dc.contributor.alternativeName | Ahn, Chul Min | - |
dc.contributor.alternativeName | Jang, Yang Soo | - |
dc.contributor.alternativeName | Choi, Dong Hoon | - |
dc.contributor.alternativeName | Hong, Myeong Ki | - |
dc.contributor.alternativeName | Hong, Sung Jin | - |
dc.contributor.affiliatedAuthor | 고영국 | - |
dc.contributor.affiliatedAuthor | 김병극 | - |
dc.contributor.affiliatedAuthor | 김중선 | - |
dc.contributor.affiliatedAuthor | 안철민 | - |
dc.contributor.affiliatedAuthor | 장양수 | - |
dc.contributor.affiliatedAuthor | 최동훈 | - |
dc.contributor.affiliatedAuthor | 홍명기 | - |
dc.contributor.affiliatedAuthor | 홍성진 | - |
dc.citation.volume | 82 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 2745 | - |
dc.citation.endPage | 2752 | - |
dc.identifier.bibliographicCitation | CIRCULATION JOURNAL, Vol.82(11) : 2745-2752, 2018 | - |
dc.identifier.rimsid | 59204 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.