Cited 0 times in
Impact of the Respiratory Motion and Longitudinal Profile on Helical Tomotherapy
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김진성 | - |
dc.contributor.author | 박광우 | - |
dc.contributor.author | 안소현 | - |
dc.contributor.author | 이호 | - |
dc.date.accessioned | 2018-08-28T17:28:23Z | - |
dc.date.available | 2018-08-28T17:28:23Z | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 1226-5829 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/162653 | - |
dc.description.abstract | The TomoTherapy® beam-delivery method creates helical beam-junctioning patterns in the dose distribution within the target. In addition, the dose discrepancy results in the particular region where the resonance by pattern of dose delivery occurs owing to the change in the position and shape of internal organs with a patient's respiration during long treatment times. In this study, we evaluated the dose pattern of the longitudinal profile with the change in respiration. The superiorinferior motion signal of the programmable respiratory motion phantom was obtained using AbChes as a four-dimensional computed tomography (4DCT) original moving signal. We delineated virtual targets in the phantom and planned to deliver the prescription dose of 300 cGy using field widths of 1.0 cm, 2.5 cm, and 5.0 cm. An original moving signal was fitted to reflecting the beam delivery time of the TomoTherapy®. The EBT3 film was inserted into the phantom movement cassette, and static, without the movement and with the original movement, was measured with signal changes of 2.0 s, 4.0 s, and 5.0 s periods, and 2.0 mm and 4.0 mm amplitudes. It was found that a dose fluctuation within ±4.0% occurred in all longitudinal profiles. Compared with the original movement, the region of the gamma index above 1 partially appeared within the target and the border of the target when the period and amplitude were changed. Gamma passing rates were 95.00% or more. However, cases for a 5.0 s period and 4.0 mm amplitude at a field width of 2.5 cm and for 2.0 s and 5.0 s periods at a field width of 5.0 cm have gamma passing rates of 92.73%, 90.31%, 90.31%, and 93.60%. TomoTherapy® s hows a s mall d ifference i n d ose d istribution according to the changes of period and amplitude of respiration. Therefore, to treat a variable respiratory motion region, a margin reflecting the degree of change of respiration signal is required. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean, English | - |
dc.publisher | 한국의학물리학회 | - |
dc.relation.isPartOf | Korean Journal of Medical Physics (의학물리) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Impact of the Respiratory Motion and Longitudinal Profile on Helical Tomotherapy | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Radiation Oncology | - |
dc.contributor.googleauthor | So Hyun Park | - |
dc.contributor.googleauthor | Jinhyun Choi | - |
dc.contributor.googleauthor | JinSung Kim | - |
dc.contributor.googleauthor | Sohyun Ahn | - |
dc.contributor.googleauthor | Min Joo Kim | - |
dc.contributor.googleauthor | Ho Lee | - |
dc.contributor.googleauthor | Seo Hee Choi | - |
dc.contributor.googleauthor | Kwangwoo Park | - |
dc.identifier.doi | 10.14316/pmp.2018.29.1.1 | - |
dc.contributor.localId | A04548 | - |
dc.contributor.localId | A01432 | - |
dc.contributor.localId | A04973 | - |
dc.contributor.localId | A03323 | - |
dc.relation.journalcode | J02057 | - |
dc.identifier.eissn | 2288-9620 | - |
dc.subject.keyword | TomoTherapy® | - |
dc.subject.keyword | 4D CT | - |
dc.subject.keyword | Moving phantom | - |
dc.subject.keyword | Period | - |
dc.subject.keyword | Amplitude | - |
dc.contributor.alternativeName | Kim, Jinsung | - |
dc.contributor.alternativeName | Park, Kwang Woo | - |
dc.contributor.alternativeName | Ahn, So Hyun | - |
dc.contributor.alternativeName | Lee, Ho | - |
dc.contributor.affiliatedAuthor | Kim, Jinsung | - |
dc.contributor.affiliatedAuthor | Park, Kwang Woo | - |
dc.contributor.affiliatedAuthor | Ahn, So Hyun | - |
dc.contributor.affiliatedAuthor | Lee, Ho | - |
dc.citation.volume | 29 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 7 | - |
dc.identifier.bibliographicCitation | Korean Journal of Medical Physics (의학물리), Vol.29(1) : 1-7, 2018 | - |
dc.identifier.rimsid | 60232 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.