Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with InCiseTM2 Multileaf Collimator

Authors
 Jeongmin Yoon  ;  Kwangwoo Park  ;  Jin Sung Kim  ;  Yong Bae Kim  ;  Ho Lee 
Citation
 Korean Journal of Medical Physics (의학물리), Vol.29(1) : 8-15, 2018 
Journal Title
Korean Journal of Medical Physics(의학물리)
ISSN
 1226-5829 
Issue Date
2018
Keywords
Robotic IMRT ; InCiseTM2 MLC ; Commissioning
Abstract
This work reports the acceptance testing and commissioning experience of the Robotic Intensity-Modulated Radiation Therapy (IMRT) M6 system with a newly released InCiseTM2 Multileaf Collimator (MLC) installed at the Yonsei Cancer Center. Acceptance testing included a mechanical interdigitation test, leaf positional accuracy, leakage check, and End-to-End (E2E) tests. Beam data measurements included tissue-phantom ratios (TPRs), off-center ratios (OCRs), output factors collected at 11 field sizes (the smallest field size was 7.6 mm×7.7 mm and largest field size was 115.0 mm×100.1 mm at 800 mm source-to-axis distance), and open beam profiles. The beam model was verified by checking patient-specific quality assurance (QA) in four fiducial-inserted phantoms, using 10 intracranial and extracranial patient plans. All measurements for acceptance testing satisfied manufacturing specifications. Mean leaf position offsets using the Garden Fence test were found to be 0.01±0.06 mm and 0.07±0.05 mm for X1 and X2 leaf banks, respectively. Maximum and average leaf leakages were 0.20% and 0.18%, respectively. E2E tests for five tracking modes showed 0.26 mm (6D Skull), 0.3 mm (Fiducial), 0.26 mm (Xsight Spine), 0.62 mm (Xsight Lung), and 0.6 mm (Synchrony). TPRs, OCRs, output factors, and open beams measured under various conditions agreed with composite data provided from the manufacturer to within 2%. Patient-specific QA results were evaluated in two ways. Point dose measurements with an ion chamber were all within the 5% absolute-dose agreement, and relative-dose measurements using an array ion chamber detector all satisfied the 3%/3 mm gamma criterion for more than 90% of the measurement points. The Robotic IMRT M6 system equipped with the InCiseTM2 MLC was proven to be accurate and reliable.
Files in This Item:
T201801154.pdf Download
DOI
10.14316/pmp.2018.29.1.8
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
Yonsei Authors
Kim, Yong Bae(김용배) ORCID logo https://orcid.org/0000-0001-7573-6862
Kim, Jinsung(김진성) ORCID logo https://orcid.org/0000-0003-1415-6471
Park, Kwang Woo(박광우) ORCID logo https://orcid.org/0000-0002-9843-7985
Lee, Ho(이호) ORCID logo https://orcid.org/0000-0001-5773-6893
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/162217
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links