Cited 1 times in
Stability of lyophilized pooled sera as quality control materials for tumor marker assays in external quality assessment
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김영란 | - |
dc.contributor.author | 김정호 | - |
dc.contributor.author | 김현숙 | - |
dc.contributor.author | 박정용 | - |
dc.date.accessioned | 2018-07-20T08:30:11Z | - |
dc.date.available | 2018-07-20T08:30:11Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 0009-8981 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/161250 | - |
dc.description.abstract | BACKGROUND: External quality assessment (EQA) requires stable quality control (QC) materials. We evaluated the stability of QC materials made of lyophilized and liquid pooled sera for the tumor markers α-fetoprotein, carcinoembryonic antigen, carbohydrate antigen 125, and carbohydrate antigen 19-9. METHODS: Specimens of the 4 tumor markers were collected from the sera of patients and stored at -20°C. After sera collection and pooling, liquid or lyophilized samples were stored at -20°C, 5°C, or room temperature. Tumor markers were quantified on days 0, 1, 4, 7, 14, 30, and 90 of storage. Internal QC results were analyzed, and the effects of heat inactivation and sucrose addition were assessed. RESULTS: Heat inactivation lowered tumor marker levels in lyophilized pooled sera, whereas sucrose addition had no effect. The coefficients of variation of the internal QC results were stable, whereas those of lyophilized samples were higher than those of liquid samples. Tumor marker levels were significantly lower in lyophilized samples (p<0.05) and did not significantly differ according to storage temperature. A declining trend over time was observed for all tumor markers. CONCLUSIONS: Lyophilized QC materials are insufficiently stable for use in EQA among clinical laboratories. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Elsevier | - |
dc.relation.isPartOf | CLINICA CHIMICA ACTA | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Biomarkers, Tumor/blood* | - |
dc.subject.MESH | Blood Specimen Collection* | - |
dc.subject.MESH | Clinical Laboratory Techniques* | - |
dc.subject.MESH | Freeze Drying | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Neoplasms/blood* | - |
dc.subject.MESH | Quality Control* | - |
dc.title | Stability of lyophilized pooled sera as quality control materials for tumor marker assays in external quality assessment | - |
dc.type | Article | - |
dc.contributor.college | Others | - |
dc.contributor.department | Severance Hospital | - |
dc.contributor.googleauthor | Sunyoung Ahn | - |
dc.contributor.googleauthor | Jungyong Park | - |
dc.contributor.googleauthor | Young Ran Kim | - |
dc.contributor.googleauthor | Jeong-Ho Kim | - |
dc.contributor.googleauthor | Hyon-Suk Kim | - |
dc.identifier.doi | 10.1016/j.cca.2017.05.035 | - |
dc.contributor.localId | A04904 | - |
dc.contributor.localId | A00903 | - |
dc.contributor.localId | A01117 | - |
dc.contributor.localId | A05333 | - |
dc.relation.journalcode | J00543 | - |
dc.identifier.eissn | 1873-3492 | - |
dc.identifier.pmid | 28579142 | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0009898117302243 | - |
dc.subject.keyword | External quality assessment | - |
dc.subject.keyword | Lyophilization | - |
dc.subject.keyword | Quality control | - |
dc.subject.keyword | Stability | - |
dc.subject.keyword | Tumor marker | - |
dc.contributor.alternativeName | Kim, Young Lan | - |
dc.contributor.alternativeName | Kim, Jeong Ho | - |
dc.contributor.alternativeName | Kim, Hyon Suk | - |
dc.contributor.alternativeName | Park, Jungyong | - |
dc.contributor.affiliatedAuthor | Kim, Young Lan | - |
dc.contributor.affiliatedAuthor | Kim, Jeong Ho | - |
dc.contributor.affiliatedAuthor | Kim, Hyon Suk | - |
dc.contributor.affiliatedAuthor | Park, Jungyong | - |
dc.citation.volume | 471 | - |
dc.citation.startPage | 233 | - |
dc.citation.endPage | 242 | - |
dc.identifier.bibliographicCitation | CLINICA CHIMICA ACTA, Vol.471 : 233-242, 2017 | - |
dc.identifier.rimsid | 61172 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.