Cited 0 times in
내측 연결 임플란트에서 지대주 내부길이가 나사 풀림에 미치는 영향
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김선재 | - |
dc.contributor.author | 문홍석 | - |
dc.contributor.author | 박영범 | - |
dc.contributor.author | 이재훈 | - |
dc.date.accessioned | 2018-07-20T08:06:10Z | - |
dc.date.available | 2018-07-20T08:06:10Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 0301-2875 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/160839 | - |
dc.description.abstract | "Purpose: The purpose of this study was to evaluate whether the internal abutment length affected screw stability in an internal connection implant. Materials and methods: Twenty long internal connection implants (Replus system, 4.7 × 11.5 mm) were selected for this investigation. Abutments were assigned to four groups depending on the length of the internal connection (abutments with internal lengths of 1, 2, 3, and 4 mm, respectively). Each implant fixture specimen was embedded in resin medium and connected to an abutment with an abutment screw. A load of 100 N, applied at an angle of 30to the long axis of the implant, was repeated for 1.0 × 106 cycles. Reverse torque values (RTV) were recorded before and after loading, and the change in RTV was calculated. Data were analyzed with the Kruskal-Wallis test. Results: The change in RTV was not significantly different among the groups (P>.05). Screw loosening and fractures were not observed in any groups, and joint stability was maintained. Conclusion: The internal length of the abutment may not significantly affect the degree of screw loosening." | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | Korean, English | - |
dc.publisher | Korean Academy of Prosthodontics) | - |
dc.relation.isPartOf | Journal of Korean Academy of Prosthodontics (대한치과보철학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 내측 연결 임플란트에서 지대주 내부길이가 나사 풀림에 미치는 영향 | - |
dc.title.alternative | Influence of internal connection length on screw loosening in internal connection implants | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry | - |
dc.contributor.department | Dept. of Prosthodontics | - |
dc.contributor.googleauthor | Ji-Sun Kim | - |
dc.contributor.googleauthor | Young-Bum Park | - |
dc.contributor.googleauthor | Hynmin Choi | - |
dc.contributor.googleauthor | Sungtae Kim | - |
dc.contributor.googleauthor | Hyeon Cheol Kim | - |
dc.contributor.googleauthor | Sun Jai Kim | - |
dc.contributor.googleauthor | Hong-Seok Moon | - |
dc.contributor.googleauthor | Jae-Hoon Lee | - |
dc.identifier.doi | 10.4047/jkap.2017.55.3.251 | - |
dc.contributor.localId | A00558 | - |
dc.contributor.localId | A01395 | - |
dc.contributor.localId | A01567 | - |
dc.contributor.localId | A03091 | - |
dc.relation.journalcode | J01493 | - |
dc.identifier.eissn | 2005-3789 | - |
dc.subject.keyword | Screw loosening | - |
dc.subject.keyword | Reverse torque | - |
dc.subject.keyword | Internal connection implant | - |
dc.subject.keyword | Internal connection length | - |
dc.contributor.alternativeName | Kim, Sun Jai | - |
dc.contributor.alternativeName | Moon, Hong Seok | - |
dc.contributor.alternativeName | Park, Young Bum | - |
dc.contributor.alternativeName | Lee, Jae Hoon | - |
dc.contributor.affiliatedAuthor | Kim, Sun Jai | - |
dc.contributor.affiliatedAuthor | Moon, Hong Seok | - |
dc.contributor.affiliatedAuthor | Park, Young Bum | - |
dc.contributor.affiliatedAuthor | Lee, Jae Hoon | - |
dc.citation.volume | 55 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 251 | - |
dc.citation.endPage | 257 | - |
dc.identifier.bibliographicCitation | Journal of Korean Academy of Prosthodontics (대한치과보철학회지), Vol.55(3) : 251-257, 2017 | - |
dc.identifier.rimsid | 60723 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.