0 744

Cited 0 times in

Cited 11 times in

Validation of the Korean National Healthcare-associated Infections Surveillance System (KONIS): an intensive care unit module report

Authors
 Y.G. Kwak  ;  J.Y. Choi  ;  H.M. Yoo  ;  S-O. Lee  ;  H.B. Kim  ;  S.H. Han  ;  H.J. Choi  ;  S.R. Kim  ;  T.H. Kim  ;  H.K. Chun  ;  H-S. Koo 
Citation
 JOURNAL OF HOSPITAL INFECTION, Vol.96(4) : 377-384, 2017 
Journal Title
JOURNAL OF HOSPITAL INFECTION
ISSN
 0195-6701 
Issue Date
2017
MeSH
Cross Infection/epidemiology* ; Epidemiological Monitoring* ; Humans ; Intensive Care Units* ; Republic of Korea/epidemiology ; Sensitivity and Specificity
Keywords
Healthcare-associated infections ; KONIS ; Surveillance ; Validation
Abstract
BACKGROUND: National surveillance data should be validated to identify methodological problems within the surveillance programme and data quality issues.

AIM: To test the validity of healthcare-associated infection (HAI) rate data from the Korean National Healthcare-associated Infections Surveillance System (KONIS).

METHODS: Records from intensive care units of 12 (14.8%) of 81 participating hospitals for January-March 2014 were examined. The validation team reviewed 406 medical records of 110 patients with 114 reported HAIs - including 34 urinary tract infections (UTIs), 57 bloodstream infections (BSIs) and 23 cases of pneumonia (PNEU) - and 296 patients with no reported HAIs during one-day visits conducted in August and September 2014. The reviewers' diagnosis of HAI was regarded as the reference standard; in ambiguous cases, the KONIS Steering Committee confirmed the diagnosis of HAI.

FINDINGS: Sensitivity values for UTIs, BSIs and PNEU were 85.3%, 74.0% and 66.7%, and specificity values were 98.7%, 99.1% and 98.7%, respectively. Positive predictive values were 85.3%, 94.7% and 78.3%, and negative predictive values were 98.7%, 94.6% and 97.7%, respectively. Sensitivity for PNEU was lower than that for UTIs and BSIs. The hospitals participating in KONIS infrequently reported conditions that were not HAIs. Sensitivity for BSIs was lower in this study than in KONIS validation studies conducted in 2008 and 2010.

CONCLUSIONS: KONIS data are generally reliable; however, sensitivity for BSIs exhibited a decrease. This study shows the need for ongoing validation and continuous training of surveillance personnel to maintain the accuracy of surveillance data.
Full Text
https://www.sciencedirect.com/science/article/pii/S0195670117301895
DOI
10.1016/j.jhin.2017.04.003
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Choi, Jun Yong(최준용) ORCID logo https://orcid.org/0000-0002-2775-3315
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/160622
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links