280 451

Cited 0 times in

Comparison of COBAS AmpliPrep/COBAS TaqMan HCV Qualitative Test v2.0 with COBAS AMPLICOR Hepatitis C Virus Test v2.0 for the Qualitative Detection of Hepatitis C Virus RNA in Korean Clinical Samples

DC Field Value Language
dc.contributor.author김영란-
dc.contributor.author김현숙-
dc.contributor.author심정은-
dc.date.accessioned2018-05-10T06:44:22Z-
dc.date.available2018-05-10T06:44:22Z-
dc.date.issued2013-
dc.identifier.issn2384-2458-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/158545-
dc.description.abstractBACKGROUND: We comparatively evaluated the performance of the conventional COBAS Amplicor HCV test v2.0 (CAM; Roche Molecular Systems, USA) and the newly developed COBAS AmpliPrep/COBAS TaqMan HCV test v2.0 (CAP/CTM; Roche Molecular Systems) for qualitative detection of hepatitis C virus (HCV) RNA in clinical samples. METHODS: Six hundred serum samples (100 HCV-positive, 500 HCV-negative, as determined by CAM) were selected and analysed using the new qualitative HCV RNA test, CAP/CTM qualitative test. Results were compared by confirmatory CAP/CTM quantitative test, which is a quantitative HCV RNA real-time polymerase chain reaction by Roche Molecular Systems, and anti-HCV test (Roche Diagnostics GmbH, Germany). Twenty-two additional serum samples, which gave a gray zone result by CAM, were selected for comparison. RESULTS: The two qualitative HCV RNA assays yielded concordant results for 586 of 600 tested samples (concordance rate, 97.7%; kappa coefficient, 0.92; 95% confidence interval [CI], 0.87 to 0.96; P<0.001). Upon re-testing by CAM, we found that the concordance rate increased to 98.2% (kappa coefficient, 0.93; 95% CI, 0.89 to 0.97; P<0.001). The additional 22 samples showing gray zone results for CAM were retested and were also tested by CAP/CTM. The results for 13 of these samples changed to negative and were now concordant with the CAP/CTM and confirmatory CAP/CTM quantitative results. For the remaining samples, the results were variable. For all the 22 samples, the results of the new CAP/CTM were in agreement with those obtained by confirmatory CAP/CTM quantitative test. CONCLUSIONS: The results of the two assays were in good agreement, with 97.7% concordance rate. However, CAP/CTM is more sensitive than CAM and showed no gray zone results. Therefore, it can be a more efficient and useful test for the qualitative detection of HCV RNA in clinical samples.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한임상검사정도관리협회-
dc.relation.isPartOfJournal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleComparison of COBAS AmpliPrep/COBAS TaqMan HCV Qualitative Test v2.0 with COBAS AMPLICOR Hepatitis C Virus Test v2.0 for the Qualitative Detection of Hepatitis C Virus RNA in Korean Clinical Samples-
dc.typeArticle-
dc.contributor.collegeOthers-
dc.contributor.departmentSeverance Hospital-
dc.contributor.googleauthorSoohun Yoo-
dc.contributor.googleauthorYounhee Park-
dc.contributor.googleauthorHwan Sub Lim-
dc.contributor.googleauthorYoung Ran Kim-
dc.contributor.googleauthorJung Eun Sim-
dc.contributor.googleauthorHyon Suk Kim-
dc.contributor.localIdA04904-
dc.contributor.localIdA01117-
dc.contributor.localIdA04971-
dc.relation.journalcodeJ01555-
dc.subject.keywordHepatitis C virus-
dc.subject.keywordQualitative HCV RNA assay-
dc.subject.keywordCOBAS Amplicor-
dc.subject.keywordCOBAS AmpliPrep/Cobas TaqMan-
dc.subject.keywordQuantitative HCV RNA real-time polymerase chain reaction (PCR)-
dc.contributor.alternativeNameKim, Young Lan-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.alternativeNameShim, Jung Eun-
dc.contributor.affiliatedAuthorKim, Young Lan-
dc.contributor.affiliatedAuthorKim, Hyon Suk-
dc.contributor.affiliatedAuthorShim, Jung Eun-
dc.citation.volume35-
dc.citation.number2-
dc.citation.startPage93-
dc.citation.endPage99-
dc.identifier.bibliographicCitationJournal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리), Vol.35(2) : 93-99, 2013-
dc.identifier.rimsid43135-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.