Digital tomosynthesis (DTS) with a Circular X-ray tube: Its image reconstruction based on total-variation minimization and the image characteristics

DC Field Value Language
dc.contributor.author장원석-
dc.date.accessioned2018-05-10T06:42:25Z-
dc.date.available2018-05-10T06:42:25Z-
dc.date.issued2013-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/158470-
dc.description.abstractIn this paper, we introduce an effective imaging system for digital tomosynthesis (DTS) with a circular X-ray tube, the so-called circular-DTS (CDTS) system, and its image reconstruction algorithm based on the total-variation (TV) minimization method for low-dose, high-accuracy X-ray imaging. Here, the X-ray tube is equipped with a series of cathodes distributed around a rotating anode, and the detector remains stationary throughout the image acquisition. We considered a TV-based reconstruction algorithm that exploited the sparsity of the image with substantially high image accuracy. We implemented the algorithm for the CDTS geometry and successfully reconstructed images of high accuracy. The image characteristics were investigated quantitatively by using some figures of merit, including the universal-quality index (UQI) and the depth resolution. For selected tomographic angles of 20, 40, and 60◦, the corresponding UQI values in the tomographic view were estimated to be about 0.94, 0.97, and 0.98, and the depth resolutions were about 4.6,3.1, and 1.2 voxels in full width at half maximum (FWHM), respectively. We expect the proposed method to be applicable to developing a next-generation dental or breast X-ray imaging system.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherKorean Physical Society-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleDigital tomosynthesis (DTS) with a Circular X-ray tube: Its image reconstruction based on total-variation minimization and the image characteristics-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Medical Engineering-
dc.contributor.googleauthorY. O. Park-
dc.contributor.googleauthorD. K. Hong-
dc.contributor.googleauthorHyosung Cho-
dc.contributor.googleauthorU. K. Je-
dc.contributor.googleauthorJ. E. Oh-
dc.contributor.googleauthorM. S. Lee-
dc.contributor.googleauthorH.J. Kim-
dc.contributor.googleauthorS.-H. Lee-
dc.contributor.googleauthorW. S. Jang-
dc.contributor.googleauthorH. M. Cho-
dc.contributor.googleauthorS. I. Choi-
dc.contributor.googleauthorY. S. Koo-
dc.contributor.localIdA04793-
dc.relation.journalcodeJ02927-
dc.identifier.urlhttps://link.springer.com/article/10.3938/jkps.63.1060-
dc.subject.keywordDigital tomosynthesis-
dc.subject.keywordCircular X-ray tube-
dc.subject.keywordTotal variation-
dc.subject.keywordLow dose-
dc.contributor.alternativeNameChang, Won Seok-
dc.contributor.affiliatedAuthorChang, Won Seok-
dc.citation.volume63-
dc.citation.number5-
dc.citation.startPage1060-
dc.citation.endPage1065-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, Vol.63(5) : 1060-1065, 2013-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.