Abstract
Purpose : This study was to compare the cumulative survival rate (CSR) of Brånemark machined surface implants and TiUnite™ imlants and to analyze association between risk factors and the CSR of the implants. Materials and methods : A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Brånemark machined and TiUnite™ implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite™ implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (α=.05). Results : Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Brånemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite™ implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Brånemark and Nobel Biocare TiUnite™ during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite™ implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification. Conclusion : Clinical performance of Brånemark machined and TiUnite™ implant demonstrated a high level of predictability. In this study, TiUnite™ implant was more successful than machined implant. The implant CSR was associated with several risk factors.
Files in This Item:
T201206351.pdf Download
DOI
10.4047/jkap.2012.50.1.61
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jong Eun(김종은) ORCID logo https://orcid.org/0000-0002-7834-2524
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/158328
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links