0 538

Cited 0 times in

KTX 객실내 부유미생물 오염현황 조사

DC Field Value Language
dc.contributor.author김창수-
dc.date.accessioned2018-05-10T06:33:18Z-
dc.date.available2018-05-10T06:33:18Z-
dc.date.issued2011-
dc.identifier.issn1738-4125-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/158183-
dc.description.abstractThe objective of this study is to assess a level of microbial contamination in the KTX. Investigation sites in the KTX were cabin, gateway, toilet and passenger seat. It was found that the mean concentrations of airborne bacteria and fungi were 157 CFU/㎥ and 84 CFU/㎥ , respectively, in all of the investigation sites of the KTX. They did not exceed the domestic standard (800 CFU/㎥) for airborne bacteria and the guideline (150 CFU/㎥ ) for airborne fungi recommended by WHO. Mean levels of bacteria and fungi distributed in passenger seat were 2.6×105 cfu/㎥ and 3.7×104 cfu/㎥ , respectively. The predominant genera identified in the KTX were Bacillus, Corynebacterium, Staphylococcus and Micrococcus for bacteria and Aspergillus, Cladosporium and Penicillium for fungi, respectively. Based on identification result, the profiles of airborne bacteria and fungi in the KTX was wholly similar to those of bacteria and fungi distributed in the passenger seat.-
dc.description.statementOfResponsibilityrestriction-
dc.languageKorean-
dc.publisher한국실내환경학회-
dc.relation.isPartOfJournal of Korean Society for Indoor Environment (한국실내환경학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleKTX 객실내 부유미생물 오염현황 조사-
dc.title.alternativeInvestigation of airborne microorganism in cabin of the KTX-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Preventive Medicine-
dc.contributor.googleauthor권순박-
dc.contributor.googleauthor박덕신-
dc.contributor.googleauthor조영민-
dc.contributor.googleauthor박재형-
dc.contributor.googleauthor김세영-
dc.contributor.googleauthor박은영-
dc.contributor.googleauthor김창수-
dc.contributor.googleauthor김기연-
dc.contributor.localIdA01042-
dc.relation.journalcodeJ01537-
dc.identifier.urlhttp://digital.kyobobook.co.kr/digital/article/articleDetail.ink?selectedLargeCategory=006&barcode=4010023210847-
dc.subject.keywordKTX-
dc.subject.keywordbacteria-
dc.subject.keywordfungi-
dc.subject.keywordcabin-
dc.subject.keywordidentification-
dc.contributor.alternativeNameKim, Chang Soo-
dc.contributor.affiliatedAuthorKim, Chang Soo-
dc.citation.volume8-
dc.citation.number1-
dc.citation.startPage11-
dc.citation.endPage19-
dc.identifier.bibliographicCitationJournal of Korean Society for Indoor Environment (한국실내환경학회지), Vol.8(1) : 11-19, 2011-
dc.identifier.rimsid48937-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Preventive Medicine (예방의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.