0 610

Cited 6 times in

Analytical Performance of Multiplex Real-Time PCR for Six Sexually Transmitted Pathogens

DC Field Value Language
dc.contributor.author김윤정-
dc.contributor.author이경아-
dc.date.accessioned2018-03-26T17:01:10Z-
dc.date.available2018-03-26T17:01:10Z-
dc.date.issued2015-
dc.identifier.issn1433-6510-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/157078-
dc.description.abstractBACKGROUND: Most organisms that cause sexual transmitted diseases (STDs) are fastidious pathogens that are difficult to detect with conventional microbiological methods and the proportions of multiple infections were noted up to 39.3% among the STI-positive subjects. However, only a few multiplex PCR and multiplex real-time PCR tests that can screen more than six microorganisms that cause STDs have been assessed. METHODS: A total of 114 endocervical swabs (ThinPrep PAPTEST PreservCyt Solution, Hologic Inc., Marlborough, MA, USA) were collected from healthy Korean women. Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), Mycoplasma genitalium (MG), Mycoplasma hominis (MH), Ureaplasma urealyticum (UU), and Trichomonas vaginalis (TV) were detected by uniplex PCR with Seeplex kits and by multiplex real-time PCR with Real-Q Kits (Biosewoom Inc., Seoul, Korea). To evaluate analytical sensitivity, plasmids containing target genes from CT, NG, MG, MH, UU, and TV were serially diluted five times with saline buffer and replicated eight times per dilution. RESULTS: Real-Q STIs Kit assays showed 100% sensitivity for detecting MH, MG, CT, TV, NG and 94.1% sensitivity for detecting UU. In addition, it showed 100% specificity for UU, MH, MG, CT, TV, and NG. The analytic sensitivity of UU (95% probit = 17.3 copy/μL, 95% CI = 11.6 to 138.6) and MH (95% probit = 30.9 copy/μL, 95% CI = 20.6 to 169.9) was relatively lower than for others pathogens. Thus, the cutoff Ct value of < 45 for UU and MH and a cutoff Ct value of < 38 for CT, MH, NG, TV could minimize differences in detection limit among the six STIs (95% probit values = 5.3 to 14.6) and to optimize overall diagnostic performance. CONCLUSIONS: For medical applications of a multiplex real-time PCR assay, one kind of cutoff value, which is according to manufacturer's instructions, was generally used without the consideration of lowest actual detectable concentration of each target substance. However, analytical performance at the low concentration limit often defines the ability of the test to diagnose disease and determine treatment endpoints. Therefore, suitable cutoffs for negative or positive screens by multiplex real-time PCR should be evaluated for accurate diagnosis.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish, German-
dc.publisherClinical Laboratory Publications-
dc.relation.isPartOfCLINICAL LABORATORY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHBacteria/classification-
dc.subject.MESHBacteria/genetics-
dc.subject.MESHBacteria/isolation & purification*-
dc.subject.MESHCervix Uteri/microbiology-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMultiplex Polymerase Chain Reaction/methods*-
dc.subject.MESHReal-Time Polymerase Chain Reaction/methods*-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHSexually Transmitted Diseases/microbiology*-
dc.titleAnalytical Performance of Multiplex Real-Time PCR for Six Sexually Transmitted Pathogens-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Laboratory Medicine-
dc.contributor.googleauthorKim Y-
dc.contributor.googleauthorKim J-
dc.contributor.googleauthorLee KA-
dc.identifier.doi10.7754/clin.lab.2015.150413-
dc.contributor.localIdA00793-
dc.contributor.localIdA02647-
dc.relation.journalcodeJ02906-
dc.identifier.pmid26732001-
dc.identifier.urlhttps://www.clin-lab-publications.com/article/1974-
dc.contributor.alternativeNameKim, Yoon Jung-
dc.contributor.alternativeNameLee, Kyung A-
dc.contributor.affiliatedAuthorKim, Yoon Jung-
dc.contributor.affiliatedAuthorLee, Kyung A-
dc.citation.volume61-
dc.citation.number11-
dc.citation.startPage1749-
dc.citation.endPage1754-
dc.identifier.bibliographicCitationCLINICAL LABORATORY, Vol.61(11) : 1749-1754, 2015-
dc.identifier.rimsid41642-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.