Cited 0 times in
Cited 60 times in
Low-interference washing-free electrochemical immunosensor using glycerol-3-phosphate dehydrogenase as an enzyme label
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김신영 | - |
dc.date.accessioned | 2018-03-26T16:42:51Z | - |
dc.date.available | 2018-03-26T16:42:51Z | - |
dc.date.issued | 2015 | - |
dc.identifier.issn | 0003-2700 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/156743 | - |
dc.description.abstract | In washing-free electrochemical detection, various redox and reactive species cause significant interference. To minimize this interference, we report a washing-free electrochemical immunosensor using flavin adenine dinucleotide (FAD)-dependent glycerol-3-phosphate dehydrogenase (GPDH) and glycerol-3-phosphate (GP) as an enzyme label and its substrate, respectively, because the reaction of FAD-dependent dehydrogenases with dissolved O2 is slow and the level of GP preexisting in blood is low (<0.1 mM). A combination of a low electrocatalytic indium-tin oxide (ITO) electrode and fast electron-mediating Ru(NH3)6(3+) is employed to obtain a high signal-to-background ratio via proximity-dependent electron mediation of Ru(NH3)6(3+) between the ITO electrode and the GPDH label. Electrochemical oxidation of GPDH-generated Ru(NH3)6(2+) is performed at 0.05 V vs Ag/AgCl, at which point the electrochemical interference is very low. When a washing-free immunosensor is applied to cardiac troponin I detection in human serum, the calculated detection limit is approximately 10 pg/mL, indicating that the immunosensor is very sensitive in spite of the use of washing-free detection with a short detection period (10 min for incubation and 100 s for electrochemical measurement). The low-interference washing-free electrochemical immunosensor shows good promise for fast and simple point-of-care testing. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | American Chemical Society | - |
dc.relation.isPartOf | ANALYTICAL CHEMISTRY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Antibodies, Immobilized/chemistry | - |
dc.subject.MESH | Biosensing Techniques/methods | - |
dc.subject.MESH | Electrochemical Techniques/methods* | - |
dc.subject.MESH | Electrodes | - |
dc.subject.MESH | Glycerolphosphate Dehydrogenase | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Immunoenzyme Techniques/methods* | - |
dc.subject.MESH | Limit of Detection | - |
dc.subject.MESH | Tin Compounds/chemistry | - |
dc.subject.MESH | Troponin I/analysis | - |
dc.subject.MESH | Troponin I/blood* | - |
dc.title | Low-interference washing-free electrochemical immunosensor using glycerol-3-phosphate dehydrogenase as an enzyme label | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Laboratory Medicine | - |
dc.contributor.googleauthor | Gorachand Dutta,† Seonhwa Park,† Amardeep Singh,† Jeongwook Seo,† Sinyoung Kim | - |
dc.contributor.googleauthor | Haesik Yang | - |
dc.identifier.doi | 10.1021/ac504485a | - |
dc.contributor.localId | A00675 | - |
dc.relation.journalcode | J00136 | - |
dc.identifier.eissn | 1520-6882 | - |
dc.identifier.pmid | 25751001 | - |
dc.identifier.url | http://pubs.acs.org/doi/10.1021/ac504485a | - |
dc.contributor.alternativeName | Kim, Sin Young | - |
dc.contributor.affiliatedAuthor | Kim, Sin Young | - |
dc.citation.volume | 87 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 3574 | - |
dc.citation.endPage | 3578 | - |
dc.identifier.bibliographicCitation | ANALYTICAL CHEMISTRY, Vol.87(7) : 3574-3578, 2015 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.