0 617

Cited 26 times in

Prognosis of high sinus heart rate after catheter ablation for atrial fibrillation

DC Field Value Language
dc.contributor.author김종윤-
dc.contributor.author김태훈-
dc.contributor.author박희남-
dc.contributor.author엄재선-
dc.contributor.author유희태-
dc.contributor.author이문형-
dc.contributor.author정보영-
dc.date.accessioned2017-10-26T08:31:38Z-
dc.date.available2017-10-26T08:31:38Z-
dc.date.issued2017-
dc.identifier.issn1099-5129-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/153266-
dc.description.abstractAIMS: Although atrial fibrillation (AF) catheter ablation increases sinus heart rate (HR), its mechanism and prognosis have not yet been clearly elucidated. We hypothesize that post-AF ablation high sinus HR (PA-HSR) is associated with a better clinical outcome of AF ablation without adverse cardiac effects. METHODS AND RESULTS: We studied 991 AF patients (75% male, 58 ± 11 years old, 70% paroxysmal AF) with HR variability (HRV) at 3 months and 1 year after catheter ablation, and pre- and post-1-year echocardiograms. Post-AF ablation high sinus HR was defined as an average HR greater than 2 SD (≥92 bpm) as measured by 24 h Holter. (1) Average HR increased significantly (P< 0.001), and PA-HSR was observed in 28 patients (2.8%) 3 months after AF ablation. At 1 year after catheter ablation, 21% were taking β-blockers and 36% maintained an average HR of ≥92 bpm. (2) Post-AF ablation high sinus HR was independently associated with pre-procedural high average HR (OR 1.097; 95% CI 1.029-1.169, P= 0.005), high left atrium (LA) electrogram voltage (OR 3.545; 95% CI 1.183-10.618, P= 0.024), and reduced root mean square of differences between successive NN intervals (rMSSD) at 3 months HRV (OR 0.959; 95% CI 0.919-0.999, P= 0.047). (3) At 1 year echocardiography, size reduction of LA (P= 0.055) or LV (P= 0.372) and the improvement in ejection fraction (P= 0.529) were not significantly different between patients with PA-HSR and those without. (4) Throughout 27 ± 17 months of follow-up, patients with PA-HSR showed significantly lower clinical recurrence than those without (log rank, P= 0.020). CONCLUSION: Post-AF ablation high sinus HR was observed in patients with smaller LA size and higher LA electrogram voltage and significant vagal modulation without adverse cardiac effects. Post-AF ablation high sinus HR was associated with a significantly lower clinical recurrence of AF after catheter ablation.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherOxford University Press-
dc.relation.isPartOfEUROPACE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titlePrognosis of high sinus heart rate after catheter ablation for atrial fibrillation-
dc.typeArticle-
dc.publisher.locationEngland-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Internal Medicine-
dc.contributor.googleauthorHee Tae Yu-
dc.contributor.googleauthorTae-Hoon Kim-
dc.contributor.googleauthorJae-Sun Uhm-
dc.contributor.googleauthorJong-Youn Kim-
dc.contributor.googleauthorBoyoung Joung-
dc.contributor.googleauthorMoon-Hyoung Lee-
dc.contributor.googleauthorHui-Nam Pak-
dc.identifier.doi10.1093/europace/euw142-
dc.contributor.localIdA01085-
dc.contributor.localIdA01776-
dc.contributor.localIdA02337-
dc.contributor.localIdA02535-
dc.contributor.localIdA02766-
dc.contributor.localIdA03609-
dc.contributor.localIdA00926-
dc.relation.journalcodeJ00801-
dc.identifier.eissn1532-2092-
dc.identifier.pmid27256421-
dc.identifier.urlhttps://academic.oup.com/europace/article-lookup/doi/10.1093/europace/euw142-
dc.contributor.alternativeNameKim, Jong Youn-
dc.contributor.alternativeNameKim, Tae Hoon-
dc.contributor.alternativeNamePak, Hui Nam-
dc.contributor.alternativeNameUhm, Jae Sun-
dc.contributor.alternativeNameYu, Hee Tae-
dc.contributor.alternativeNameLee, Moon Hyoung-
dc.contributor.alternativeNameJoung, Bo Young-
dc.contributor.affiliatedAuthorKim, Tae-Hoon-
dc.contributor.affiliatedAuthorPak, Hui Nam-
dc.contributor.affiliatedAuthorUhm, Jae Sun-
dc.contributor.affiliatedAuthorYu, Hee Tae-
dc.contributor.affiliatedAuthorLee, Moon Hyoung-
dc.contributor.affiliatedAuthorJoung, Bo Young-
dc.contributor.affiliatedAuthorKim, Jong Youn-
dc.citation.titleEuropace-
dc.citation.volume19-
dc.citation.date2017-
dc.citation.startPage1132-
dc.citation.endPage1139-
dc.identifier.bibliographicCitationEUROPACE, Vol.19 : 1132-1139, 2017-
dc.date.modified2017-10-24-
dc.identifier.rimsid41540-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.