Cited 26 times in
Prognosis of high sinus heart rate after catheter ablation for atrial fibrillation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김종윤 | - |
dc.contributor.author | 김태훈 | - |
dc.contributor.author | 박희남 | - |
dc.contributor.author | 엄재선 | - |
dc.contributor.author | 유희태 | - |
dc.contributor.author | 이문형 | - |
dc.contributor.author | 정보영 | - |
dc.date.accessioned | 2017-10-26T08:31:38Z | - |
dc.date.available | 2017-10-26T08:31:38Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 1099-5129 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/153266 | - |
dc.description.abstract | AIMS: Although atrial fibrillation (AF) catheter ablation increases sinus heart rate (HR), its mechanism and prognosis have not yet been clearly elucidated. We hypothesize that post-AF ablation high sinus HR (PA-HSR) is associated with a better clinical outcome of AF ablation without adverse cardiac effects. METHODS AND RESULTS: We studied 991 AF patients (75% male, 58 ± 11 years old, 70% paroxysmal AF) with HR variability (HRV) at 3 months and 1 year after catheter ablation, and pre- and post-1-year echocardiograms. Post-AF ablation high sinus HR was defined as an average HR greater than 2 SD (≥92 bpm) as measured by 24 h Holter. (1) Average HR increased significantly (P< 0.001), and PA-HSR was observed in 28 patients (2.8%) 3 months after AF ablation. At 1 year after catheter ablation, 21% were taking β-blockers and 36% maintained an average HR of ≥92 bpm. (2) Post-AF ablation high sinus HR was independently associated with pre-procedural high average HR (OR 1.097; 95% CI 1.029-1.169, P= 0.005), high left atrium (LA) electrogram voltage (OR 3.545; 95% CI 1.183-10.618, P= 0.024), and reduced root mean square of differences between successive NN intervals (rMSSD) at 3 months HRV (OR 0.959; 95% CI 0.919-0.999, P= 0.047). (3) At 1 year echocardiography, size reduction of LA (P= 0.055) or LV (P= 0.372) and the improvement in ejection fraction (P= 0.529) were not significantly different between patients with PA-HSR and those without. (4) Throughout 27 ± 17 months of follow-up, patients with PA-HSR showed significantly lower clinical recurrence than those without (log rank, P= 0.020). CONCLUSION: Post-AF ablation high sinus HR was observed in patients with smaller LA size and higher LA electrogram voltage and significant vagal modulation without adverse cardiac effects. Post-AF ablation high sinus HR was associated with a significantly lower clinical recurrence of AF after catheter ablation. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Oxford University Press | - |
dc.relation.isPartOf | EUROPACE | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Prognosis of high sinus heart rate after catheter ablation for atrial fibrillation | - |
dc.type | Article | - |
dc.publisher.location | England | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Internal Medicine | - |
dc.contributor.googleauthor | Hee Tae Yu | - |
dc.contributor.googleauthor | Tae-Hoon Kim | - |
dc.contributor.googleauthor | Jae-Sun Uhm | - |
dc.contributor.googleauthor | Jong-Youn Kim | - |
dc.contributor.googleauthor | Boyoung Joung | - |
dc.contributor.googleauthor | Moon-Hyoung Lee | - |
dc.contributor.googleauthor | Hui-Nam Pak | - |
dc.identifier.doi | 10.1093/europace/euw142 | - |
dc.contributor.localId | A01085 | - |
dc.contributor.localId | A01776 | - |
dc.contributor.localId | A02337 | - |
dc.contributor.localId | A02535 | - |
dc.contributor.localId | A02766 | - |
dc.contributor.localId | A03609 | - |
dc.contributor.localId | A00926 | - |
dc.relation.journalcode | J00801 | - |
dc.identifier.eissn | 1532-2092 | - |
dc.identifier.pmid | 27256421 | - |
dc.identifier.url | https://academic.oup.com/europace/article-lookup/doi/10.1093/europace/euw142 | - |
dc.contributor.alternativeName | Kim, Jong Youn | - |
dc.contributor.alternativeName | Kim, Tae Hoon | - |
dc.contributor.alternativeName | Pak, Hui Nam | - |
dc.contributor.alternativeName | Uhm, Jae Sun | - |
dc.contributor.alternativeName | Yu, Hee Tae | - |
dc.contributor.alternativeName | Lee, Moon Hyoung | - |
dc.contributor.alternativeName | Joung, Bo Young | - |
dc.contributor.affiliatedAuthor | Kim, Tae-Hoon | - |
dc.contributor.affiliatedAuthor | Pak, Hui Nam | - |
dc.contributor.affiliatedAuthor | Uhm, Jae Sun | - |
dc.contributor.affiliatedAuthor | Yu, Hee Tae | - |
dc.contributor.affiliatedAuthor | Lee, Moon Hyoung | - |
dc.contributor.affiliatedAuthor | Joung, Bo Young | - |
dc.contributor.affiliatedAuthor | Kim, Jong Youn | - |
dc.citation.title | Europace | - |
dc.citation.volume | 19 | - |
dc.citation.date | 2017 | - |
dc.citation.startPage | 1132 | - |
dc.citation.endPage | 1139 | - |
dc.identifier.bibliographicCitation | EUROPACE, Vol.19 : 1132-1139, 2017 | - |
dc.date.modified | 2017-10-24 | - |
dc.identifier.rimsid | 41540 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.