547 755

Cited 0 times in

Real-time PCR을 이용한 Epstein-Barr Virus DNA 검사 평가

DC Field Value Language
dc.contributor.author김현숙-
dc.contributor.author심정은-
dc.date.accessioned2017-10-26T08:13:10Z-
dc.date.available2017-10-26T08:13:10Z-
dc.date.issued2016-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/153152-
dc.description.abstractBackground : Epstein-Barr virus (EBV) is known to be the causative agent of infectious mononucleosis and EBV-related malignancies. In this study, we compared the results of three real-time PCR kits for EBV DNA assays. Methods : A total of 300 whole blood samples submitted for quantitative EBV PCR between January 2013 and September 2014 at Severance Hospital were included. The samples were tested by using the Artus EBV RG PCR Kit (Qiagen, Germany), AccuPower EBV Quantitative PCR Kit (Bioneer, Korea), and Real-Q EBV Kit (BioSewoom, Korea). Samples with discordant results between the three kits were confirmed by direct sequencing. Results : The result concordance rate and kappa coefficient (K) were 86.3% and 0.69 for Artus-AccuPower, 93.3% and 0.85 for Artus-Real-Q, and 92.3% and 0.83 for AccuPower-Real-Q, respectively. The correlations between the three kits were found to be significant, with a correlation coefficient of r=0.854 for Artus-AccuPower, -0.802 for Artus-Real-Q, and -0.977 for AccuPower-Real-Q, respectively (P<0.0001). If the real-time PCR concordant results of 258 samples and the direct sequencing results of 42 real-time PCR discordant samples were assumed to be true, the sensitivity/specificity values were 0.921/0.976 for Artus, 0.902/0.965 for AccuPower, and 0.967/1.000 for Real-Q. Conclusions : The three real-time PCR kits showed excellent sensitivities and specificities. All these kits would be acceptable for clinical and therapeutic management of EBV. However, some discordant results between the kits indicate the need for caution in clinical diagnosis and staging. Further implementation of standardized methodology would be needed for EBV DNA assays.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisherKorean Society for Laboratory Medicine-
dc.relation.isPartOfLaboratory Medicine Online-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleReal-time PCR을 이용한 Epstein-Barr Virus DNA 검사 평가-
dc.title.alternativeEvaluation of Real-time PCR Kits for Epstein-Barr Virus DNA Assays-
dc.typeArticle-
dc.publisher.locationKorea (South)-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Laboratory Medicine-
dc.contributor.googleauthor하지혜-
dc.contributor.googleauthor박용정-
dc.contributor.googleauthor심정은-
dc.contributor.googleauthor김현숙-
dc.identifier.doi10.3343/lmo.2016.6.1.31-
dc.contributor.localIdA04971-
dc.contributor.localIdA01117-
dc.relation.journalcodeJ02151-
dc.identifier.eissn2093-6338-
dc.subject.keywordEpstein-Barr virus (EBV)-
dc.subject.keywordEBV DNA-
dc.subject.keywordReal-time PCR-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.alternativeNameShim, Jung Eun-
dc.contributor.affiliatedAuthorShim, Jung Eun-
dc.contributor.affiliatedAuthorKim, Hyon Suk-
dc.citation.volume6-
dc.citation.number1-
dc.citation.startPage31-
dc.citation.endPage35-
dc.identifier.bibliographicCitationLaboratory Medicine Online, Vol.6(1) : 31-35, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid41149-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.