0 295

Cited 3 times in

Prediction of fluid responsiveness in the beach chair position using dynamic preload indices

DC FieldValueLanguage
dc.contributor.author김수영-
dc.contributor.author오영준-
dc.contributor.author이수현-
dc.contributor.author천용민-
dc.contributor.author최용선-
dc.contributor.author박상준-
dc.contributor.author신서경-
dc.date.accessioned2017-10-26T07:48:32Z-
dc.date.available2017-10-26T07:48:32Z-
dc.date.issued2016-
dc.identifier.issn1387-1307-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/152535-
dc.description.abstractHemodynamic instability in the beach chair position (BCP) may lead to adverse outcomes. Cardiac preload optimization is a prerequisite to improve hemodynamics. We evaluated the clinical usefulness of dynamic indices for the prediction of fluid responsiveness in BCP patients under general anesthesia. Forty-two patients in the BCP under mechanical ventilation received colloids at 6 ml/kg for 10 min. Stroke volume variation (SVV), pulse pressure variation (PPV), pleth variability index (PVI), and hemodynamic data were measured before and after the fluid challenge. Patients were considered responders to volume expansion if the stroke volume index increased by ≥15 %. The areas under receiver operating characteristic curves for SVV, PPV and PVI were 0.83, 0.81 and 0.74, respectively (p < 0.05), with the corresponding optimal cut-off values of 12, 15 and 10 %. SVV, PPV and PVI can be used to predict fluid responsiveness in the BCP under mechanical ventilation.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSpringer-
dc.relation.isPartOfJOURNAL OF CLINICAL MONITORING AND COMPUTING-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHAnesthesia-
dc.subject.MESHArea Under Curve-
dc.subject.MESHArthroscopy/methods-
dc.subject.MESHBlood Pressure-
dc.subject.MESHEchocardiography/methods-
dc.subject.MESHFemale-
dc.subject.MESHFluid Therapy/methods*-
dc.subject.MESHHeart Rate-
dc.subject.MESHHemodynamics*-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPatient Positioning-
dc.subject.MESHPlethysmography/methods*-
dc.subject.MESHPosture*-
dc.subject.MESHProspective Studies-
dc.subject.MESHROC Curve-
dc.subject.MESHRespiration, Artificial-
dc.subject.MESHSensitivity and Specificity-
dc.subject.MESHStroke Volume-
dc.titlePrediction of fluid responsiveness in the beach chair position using dynamic preload indices-
dc.typeArticle-
dc.publisher.locationNetherlands-
dc.contributor.collegeOthers-
dc.contributor.departmentSeverance Hospital-
dc.contributor.googleauthorSu Hyun Lee-
dc.contributor.googleauthorYong-Min Chun-
dc.contributor.googleauthorYoung Jun Oh-
dc.contributor.googleauthorSeokyung Shin-
dc.contributor.googleauthorSang Jun Park-
dc.contributor.googleauthorSoo Young Kim-
dc.contributor.googleauthorYong Seon Choi-
dc.identifier.doi10.1007/s10877-015-9821-5-
dc.contributor.localIdA02389-
dc.contributor.localIdA02897-
dc.contributor.localIdA04028-
dc.contributor.localIdA04119-
dc.contributor.localIdA04933-
dc.contributor.localIdA02109-
dc.contributor.localIdA04900-
dc.relation.journalcodeJ01326-
dc.identifier.eissn1573-2614-
dc.identifier.pmid26719298-
dc.identifier.urlhttps://link.springer.com/article/10.1007%2Fs10877-015-9821-5-
dc.subject.keywordBeach chair position-
dc.subject.keywordFluid responsiveness-
dc.subject.keywordPleth variability index-
dc.subject.keywordPulse pressure variation-
dc.subject.keywordStroke volume variation-
dc.contributor.alternativeNameKim, Soo Young-
dc.contributor.alternativeNameOh, Young Jun-
dc.contributor.alternativeNameLee, Su Hyun-
dc.contributor.alternativeNameChun, Yong Min-
dc.contributor.alternativeNameChoi, Yong Seon-
dc.contributor.alternativeNamePark, Sang Jun-
dc.contributor.alternativeNameShin, Seo Kyung-
dc.contributor.affiliatedAuthorOh, Young Jun-
dc.contributor.affiliatedAuthorLee, Su Hyun-
dc.contributor.affiliatedAuthorChun, Yong Min-
dc.contributor.affiliatedAuthorChoi, Yong Seon-
dc.contributor.affiliatedAuthorPark, Sang Jun-
dc.contributor.affiliatedAuthorShin, Seo Kyung-
dc.contributor.affiliatedAuthorKim, Soo Young-
dc.citation.volume30-
dc.citation.number6-
dc.citation.startPage995-
dc.citation.endPage1002-
dc.identifier.bibliographicCitationJOURNAL OF CLINICAL MONITORING AND COMPUTING, Vol.30(6) : 995-1002, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid48738-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.