181 404

Cited 6 times in

Spatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study

DC Field Value Language
dc.contributor.author박희남-
dc.contributor.author이문형-
dc.contributor.author정보영-
dc.date.accessioned2017-10-26T07:24:46Z-
dc.date.available2017-10-26T07:24:46Z-
dc.date.issued2016-
dc.identifier.issn1226-4512-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/151997-
dc.description.abstractAlthough 3D-complex fractionated atrial electrogram (CFAE) mapping is useful in radiofrequency catheter ablation for persistent atrial fibrillation (AF), the directions and configuration of the bipolar electrodes may affect the electrogram. This study aimed to compare the spatial reproducibility of CFAE by changing the catheter orientations and electrode distance in an in-silico left atrium (LA). We conducted this study by importing the heart CT image of a patient with AF into a 3D-homogeneous human LA model. Electrogram morphology, CFAE-cycle lengths (CLs) were compared for 16 different orientations of a virtual bipolar conventional catheter (conv-cath: size 3.5 mm, inter-electrode distance 4.75 mm). Additionally, the spatial correlations of CFAE-CLs and the percentage of consistent sites with CFAE-CL<120 ms were analyzed. The results from the conv-cath were compared with that obtained using a mini catheter (mini-cath: size 1 mm, inter-electrode distance 2.5 mm). Depending on the catheter orientation, the electrogram morphology and CFAE-CLs varied (conv-cath: 11.5±0.7% variation, mini-cath: 7.1±1.2% variation), however the mini-cath produced less variation of CFAE-CL than conv-cath (p<0.001). There were moderate spatial correlations among CFAE-CL measured at 16 orientations (conv-cath: r=0.3055±0.2194 vs. mini-cath: 0.6074±0.0733, p<0.001). Additionally, the ratio of consistent CFAE sites was higher for mini catheter than conventional one (38.3±4.6% vs. 22.3±1.4%, p<0.05). Electrograms and CFAE distribution are affected by catheter orientation and electrode configuration in the in-silico LA model. However, there was moderate spatial consistency of CFAE areas, and narrowly spaced bipolar catheters were less influenced by catheter direction than conventional catheters.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisher대한약리학회-
dc.relation.isPartOfKOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleSpatial reproducibility of complex fractionated atrial electrogram depending on the direction and configuration of bipolar electrodes: an in-silico modeling study-
dc.typeArticle-
dc.publisher.locationKorea-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Internal Medicine-
dc.contributor.googleauthorJun-Seop Song-
dc.contributor.googleauthorYoung-Seon Lee-
dc.contributor.googleauthorMinki Hwang-
dc.contributor.googleauthorJung-Kee Lee-
dc.contributor.googleauthorChangyong Li-
dc.contributor.googleauthorBoyoung Joung-
dc.contributor.googleauthorMoon-Hyoung Lee-
dc.contributor.googleauthorEun Bo Shim-
dc.contributor.googleauthorHui-Nam Pak-
dc.identifier.doi10.4196/kjpp.2016.20.5.507-
dc.contributor.localIdA02766-
dc.contributor.localIdA03609-
dc.contributor.localIdA01776-
dc.relation.journalcodeJ02104-
dc.identifier.eissn2093-3827-
dc.identifier.pmid27610037-
dc.subject.keywordAtrial fibrillation-
dc.subject.keywordBipolar electrogram-
dc.subject.keywordComplex fractionated atrial electrogram-
dc.subject.keywordComputational modeling-
dc.contributor.alternativeNamePak, Hui Nam-
dc.contributor.alternativeNameLee, Moon Hyoung-
dc.contributor.alternativeNameJoung, Bo Young-
dc.contributor.affiliatedAuthorLee, Moon Hyoung-
dc.contributor.affiliatedAuthorJoung, Bo Young-
dc.contributor.affiliatedAuthorPak, Hui Nam-
dc.citation.volume20-
dc.citation.number5-
dc.citation.startPage507-
dc.citation.endPage514-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY, Vol.20(5) : 507-514, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid46319-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.