179 525

Cited 0 times in

The changes in delivered oxygen fractions using laerdal resuscitator bag with different types of reservoir

DC Field Value Language
dc.contributor.author김기준-
dc.contributor.author남순호-
dc.contributor.author남용택-
dc.contributor.author심재광-
dc.date.accessioned2017-10-26T06:41:56Z-
dc.date.available2017-10-26T06:41:56Z-
dc.date.issued2001-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/151191-
dc.description.abstractOne of the disadvantages of the Laerdal resuscitator bag is that it does not deliver a high concentration of oxygen without a reservoir and an appropriate technique of ventilation. With a specific device that is able to compress a resuscitator bag mechanically at a regular volume, ventilator rate, and speed, we evaluated the effects of various factors (the tidal volume, the ventilator rate, the oxygen flow rate, the type of reservoir) of the Laerdal resuscitator bag during positive pressure ventilation that affect the delivered oxygen fraction (FDO2) and also whether 250 mL and 500 mL corrugated tubes could be used as substitutes for the reservoir bag. The 250 mL corrugated tube increased the FDO2 to over 96% with an oxygen flow rate of 15 L/min. The 500 mL corrugated tube increased the FDO2 to over 96% with an oxygen flow rate of 10 L/min regardless of the ventilator rate at a fixed tidal volume of 500 mL. At the identical fixed tidal volume of 500 mL, the 1,600 mL reservoir bag increased the FDO2 to over 92% with an oxygen flow rate of 5 L/min and to over 96% at 7.5 L/min regardless of the ventilator rate. We concluded that the FDO2 of the Laerdal resuscitator bag depends on various factors such as tidal volume, ventilator rate, oxygen flow rate, and type of reservoir and both the 250 mL and 500 mL corrugated tubes can be used as substitutes.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleThe changes in delivered oxygen fractions using laerdal resuscitator bag with different types of reservoir-
dc.typeArticle-
dc.publisher.locationKorea (South)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine (마취통증의학교실)-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine (마취통증의학교실)-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine (마취통증의학교실)-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine (마취통증의학교실)-
dc.contributor.googleauthorSoon Ho Nam-
dc.contributor.googleauthorKi Jun Kim-
dc.contributor.googleauthorYong Taek Nam-
dc.contributor.googleauthorJae Kwang Shim-
dc.contributor.localIdA00340-
dc.contributor.localIdA01256-
dc.contributor.localIdA01259-
dc.contributor.localIdA02205-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.contributor.alternativeNameKim, Ki Jun-
dc.contributor.alternativeNameNam, Soon Ho-
dc.contributor.alternativeNameNam, Yong Taek-
dc.contributor.alternativeNameShim, Jae Kwang-
dc.citation.volume42-
dc.citation.number2-
dc.citation.startPage242-
dc.citation.endPage246-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.42(2) : 242-246, 2001-
dc.date.modified2017-05-04-
dc.identifier.rimsid43523-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.