517 581

Cited 0 times in

혈액 투석관 내 혈류 측정을 위한 생체외 실험모델

DC Field Value Language
dc.contributor.author김유선-
dc.date.accessioned2017-05-04T07:31:56Z-
dc.date.available2017-05-04T07:31:56Z-
dc.date.issued2005-
dc.identifier.issn1226-0053-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/147419-
dc.description.abstractPurpose: Previously, we developed a new method to calculate the flow rate in the hemodialysis vascular conduit based on Bernoulli's theory for surveillance of the arteriovenous fistula (AVF) function. However, the calculated flow rate would be different from the true flow rate because due to various factors. To compare the true flow rate, with intra- conduit pressure, and the calculated flow rate, an ex vivo experimental model was developed. Methods: The arterial end of the vascular conduit was connected to a saline-filled bottle, with the venous end connected to a flow meter to control the flow rate. By monitoring the change in the true flow rate (Q) with the flow meter, each arterial and venous static pressure (pA, pV) and total pressure (pT) were observed. Using these parameters, the intra-conduit flow rates (QA, QV) were calculated by Bernoulli's equation. Finally, we compared the pA or pV with Q, and calculated the difference between the QA or QV and Q. Results: There were no statistical differences between any of the pressure measurement during the 5 consecutive 5 experiments (P<0.05). The static pressure (pA or pV) was closely correlated with Q (pA, R2=0.950, P=0.000; pV, R2= 0.952, P=0.000). The calculated flow rate (QA or QV) was not in complete in accord with Q, but was closely correlated (QA, R2=0.961, P=0.000; QV, R2=0.961, P=0.000). Conclusion: The pressure measurement and calculated flow rate indicate the nature of the true flow rate in the vascular conduit.-
dc.description.statementOfResponsibilityopen-
dc.format.extent253~257-
dc.publisher대한외과학회-
dc.relation.isPartOfJOURNAL OF THE KOREAN SURGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHPressure measurement-
dc.subject.MESHFlow rate-
dc.subject.MESHEx vivo experiment-
dc.title혈액 투석관 내 혈류 측정을 위한 생체외 실험모델-
dc.title.alternativeFlow Measurement in the Vascular Access Conduit: an Ex Vivo Experimental Model-
dc.typeArticle-
dc.publisher.locationKorea-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Surgery (외과학교실)-
dc.contributor.googleauthor이종훈-
dc.contributor.googleauthor허규하-
dc.contributor.googleauthor김유선-
dc.contributor.googleauthor조희은-
dc.contributor.googleauthor박기일-
dc.identifier.doiOAK-2005-02778-
dc.contributor.localIdA00785-
dc.relation.journalcodeJ01893-
dc.relation.journalsince1983~2011-
dc.relation.journalafter2011~ Journal of the Korean Surgical Society-
dc.subject.keywordPressure measurement-
dc.subject.keywordFlow rate-
dc.subject.keywordEx vivo experiment-
dc.contributor.alternativeNameKim, Yu Seun-
dc.citation.volume68-
dc.citation.number4-
dc.citation.startPage253-
dc.citation.endPage257-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN SURGICAL SOCIETY , Vol.68(4) : 253-257, 2005-
dc.date.modified2017-05-04-
dc.identifier.rimsid48589-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.