0 744

Cited 2 times in

Mechanical quality assurance using light field for linear accelerators with camera calibration

DC Field Value Language
dc.contributor.author금기창-
dc.contributor.author박광우-
dc.contributor.author윤정민-
dc.contributor.author이익재-
dc.contributor.author이창걸-
dc.contributor.author이호-
dc.contributor.author조재호-
dc.contributor.author최원훈-
dc.date.accessioned2017-02-24T07:45:52Z-
dc.date.available2017-02-24T07:45:52Z-
dc.date.issued2016-
dc.identifier.issn1120-1797-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/146514-
dc.description.abstractMechanical Quality Assurance (QA) is important to assure spatially precise delivery of external-beam radiation therapy. As an alternative to the conventional-film based method, we have developed a new tool for mechanical QA of LINACs which uses a light field rather than radiation. When light passes through the collimator, a shadow is projected onto a piece of translucent paper and the resulting image is captured by a digital camera via a mirror. With this method, we evaluated the position of the LINAC isocenter and the accuracy of the gantry, collimator, and couch rotation. We also evaluated the accuracy of the digital readouts of the gantry, collimator, and couch rotation. In addition, the treatment couch position indicator was tested. We performed camera calibration as an essential pre-requisite for quantitative measurements of the position of isocenter, the linear motion of the couch, and the rotation angles of the gantry and collimator. Camera calibration reduced the measurement error to submillimeter based on uncertainty in pixel size of the image, while, without calibration, the measurement error of up to 2 mm could occur for an object with a length of 5 cm.-
dc.description.statementOfResponsibilityrestriction-
dc.format.extent398~402-
dc.languageEnglish-
dc.publisherIstituti Editoriali e Poligrafici Internazionali-
dc.relation.isPartOfPHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHCalibration-
dc.subject.MESHMechanical Phenomena*-
dc.subject.MESHParticle Accelerators*-
dc.subject.MESHQuality Control-
dc.subject.MESHRadiotherapy/instrumentation*-
dc.subject.MESHRotation-
dc.titleMechanical quality assurance using light field for linear accelerators with camera calibration-
dc.typeArticle-
dc.publisher.locationItaly-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Radiation Oncology-
dc.contributor.googleauthorKwangwoo Park-
dc.contributor.googleauthorWonhoon Choi-
dc.contributor.googleauthorKi Chang Keum-
dc.contributor.googleauthorHo Lee-
dc.contributor.googleauthorJeongmin Yoon-
dc.contributor.googleauthorChang Geol Lee-
dc.contributor.googleauthorIk Jae Lee-
dc.contributor.googleauthorJaeho Cho-
dc.identifier.doi10.1016/j.ejmp.2016.01.003-
dc.contributor.localIdA00272-
dc.contributor.localIdA01432-
dc.contributor.localIdA04615-
dc.contributor.localIdA03055-
dc.contributor.localIdA03240-
dc.contributor.localIdA03323-
dc.contributor.localIdA03901-
dc.contributor.localIdA04129-
dc.relation.journalcodeJ02892-
dc.identifier.eissn1724-191X-
dc.identifier.pmid26833362-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S1120179716000053-
dc.subject.keywordCamera calibration-
dc.subject.keywordLens distortion-
dc.subject.keywordLight field-
dc.subject.keywordMechanical isocenter-
dc.subject.keywordQuality assurance (QA)-
dc.contributor.alternativeNameKeum, Ki Chang-
dc.contributor.alternativeNamePark, Kwang Woo-
dc.contributor.alternativeNameYoon, Jeongmin-
dc.contributor.alternativeNameLee, Ik Jae-
dc.contributor.alternativeNameLee, Chang Geol-
dc.contributor.alternativeNameLee, Ho-
dc.contributor.alternativeNameCho, Jae Ho-
dc.contributor.alternativeNameChoi, Won Hoon-
dc.contributor.affiliatedAuthorKeum, Ki Chang-
dc.contributor.affiliatedAuthorPark, Kwang Woo-
dc.contributor.affiliatedAuthorYoon, Jeongmin-
dc.contributor.affiliatedAuthorLee, Ik Jae-
dc.contributor.affiliatedAuthorLee, Chang Geol-
dc.contributor.affiliatedAuthorLee, Ho-
dc.contributor.affiliatedAuthorCho, Jae Ho-
dc.contributor.affiliatedAuthorChoi, Won Hoon-
dc.citation.volume32-
dc.citation.number2-
dc.citation.startPage398-
dc.citation.endPage402-
dc.identifier.bibliographicCitationPHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, Vol.32(2) : 398-402, 2016-
dc.date.modified2017-02-24-
dc.identifier.rimsid45146-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.