dc.description.abstractBackgroud: Continuous arterial blood pressure monitoring is a highly effective method in an operation and the intensive care unit. However, the accuracy of the monitoring system could be influenced by the radius and longitude of the catheter. This study was executed to examine the effects of the radius and longitude of a catheter. Methods: Forty-two pediatric patients scheduled to undergo open heart surgery were selected. After induction of anesthesia, the radial artery pressure was measured by a 22-gauge (1 inch) catheter and the femoral artery pressure was measured by a 20-gauge (1.16 inch) catheter, 22-gauge catheter and 20-gauge (12 ㎝) catheter in succession. In fluences of the radius and longitude were analysed respectively. All values are expressed as mean±SD and analysed using the paired t-test; P< 0.05 was considered significant. Results: The systolic pressure of the 20-gauge (1.16 inch) catheter was higher than that of the 22-gauge (1 inch) catheter. The systolic pressure of the 20-gauge (1.16 inch) catheter was higher than that of the 20-gauge (12 ㎝) catheter. Mean and diastolic pressures were low in the 20-gauge (1.16 inch) catheter, compared with the 20-gauge (12 ㎝) catheter. Conclusions: Shorter and/or larger radius catheters could increase the pulse pressure in pediatric patients.-
dc.description.statementOfResponsibilityopen-
dc.format.extent10~14-
dc.relation.isPartOfJournal of Korean Society of Anesthesiologist (대한마취과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title지속적 동맥압 감시시 카테테르의 길이와 내경이 동맥압 측정치에 미치는 영향 분석-
dc.title.alternativeThe Effect of the Radius and Longitude of a Catheter in Continuous Arterial Blood Pressure Monitoring-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology (마취통증의학)-
dc.contributor.googleauthor박성용-
dc.contributor.googleauthor방서욱-
dc.contributor.googleauthor곽영란-
dc.contributor.googleauthor오영준-
dc.contributor.googleauthor조혁래-
dc.contributor.googleauthor홍용우-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00172-
dc.relation.journalcodeJ01540-
dc.subject.keywordArterial blood pressure-
dc.subject.keywordarterial catheters-
dc.contributor.alternativeNameKwak, Young Lan-
dc.contributor.affiliatedAuthorKwak, Young Lan-
dc.rights.accessRightsfree-
dc.citation.volume43-
dc.citation.number1-
dc.citation.startPage10-
dc.citation.endPage14-
dc.identifier.bibliographicCitationJournal of Korean Society of Anesthesiologist (대한마취과학회지), Vol.43(1) : 10-14, 2002-
dc.identifier.rimsid55513-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.