0 810

Cited 6 times in

Evaluation of a Rapid Immunochromatographic Treponemal Antibody Test Comparing the Treponema Pallidum Particle Agglutination Assay

DC Field Value Language
dc.contributor.author김현숙-
dc.contributor.author이민걸-
dc.contributor.author이종한-
dc.date.accessioned2016-02-04T12:04:22Z-
dc.date.available2016-02-04T12:04:22Z-
dc.date.issued2015-
dc.identifier.issn0887-8013-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/141829-
dc.description.abstractBACKGROUND: In addition to conventional tests, several methods for detection of treponema-specific antibodies in clinical settings have been recently introduced. We aim to comparatively evaluate a rapid immunochromatographic test (ICT) for Treponema pallidum specific antibody (SD Bioline Syphilis 3.0) and the T. pallidum particle agglutination (TPPA) assay. METHODS: In all, 132 serum samples from 78 syphilis patients and 54 syphilis-negative controls were analyzed. SD Bioline Syphilis 3.0 test (Standard Diagnostic, Inc., Yongin, Korea) was evaluated and compared to Serodia TPPA assay (Fujirebio, Inc., Tokyo, Japan). All discrepant results between the two assays were repeatedly tested and evaluated by the fluorescent treponemal antibody-absorption (FTA-ABS) assay. Test reproducibility and 95% limit of detection of SD Bioline Syphilis 3.0 were determined across three different lots for seven consecutive days in triplicate. Interference due to autoantibodies and pregnancy was also tested. RESULTS: Percent agreement between SD Bioline Syphilis 3.0 and TPPA assays was 99.2%. Sensitivity and specificity were 100%, respectively. In TPPA assay, test-to-test, day-to-day, and lot-to-lot variations were not identified until 1:320 titer (eightfold dilutions). There was no interference due to the presence of antinuclear antibodies or samples or pregnancy. CONCLUSIONS: Percent agreement of SD Syphilis 3.0 and TPPA was very good. Sensitivity and specificity were appropriate for T. pallidum antibody detection. Thus, a rapid ICT could be suitable for syphilis antibody detection.-
dc.description.statementOfResponsibilityopen-
dc.format.extent383~386-
dc.relation.isPartOfJOURNAL OF CLINICAL LABORATORY ANALYSIS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAntibodies, Bacterial/blood*-
dc.subject.MESHCase-Control Studies-
dc.subject.MESHHumans-
dc.subject.MESHImmunochromatography/methods*-
dc.subject.MESHLimit of Detection-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSyphilis/diagnosis*-
dc.subject.MESHSyphilis Serodiagnosis/methods*-
dc.subject.MESHTreponema pallidum/immunology-
dc.subject.MESHTreponema pallidum/isolation & purification*-
dc.titleEvaluation of a Rapid Immunochromatographic Treponemal Antibody Test Comparing the Treponema Pallidum Particle Agglutination Assay-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Dermatology (피부과학)-
dc.contributor.googleauthorJong-Han Lee-
dc.contributor.googleauthorChae Seung Lim-
dc.contributor.googleauthorHyon-Suk Kim-
dc.contributor.googleauthorMin-Geol Lee-
dc.identifier.doi10.1002/jcla.21783-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02779-
dc.contributor.localIdA03151-
dc.contributor.localIdA01117-
dc.relation.journalcodeJ01323-
dc.identifier.eissn1098-2825-
dc.identifier.pmid25385043-
dc.identifier.urlhttp://onlinelibrary.wiley.com/doi/10.1002/jcla.21783/abstract-
dc.subject.keywordSyphilis-
dc.subject.keywordTreponema pallidum particle agglutination (TPPA)-
dc.subject.keywordagreement-
dc.subject.keywordrapid immunochromatographic test-
dc.contributor.alternativeNameKim, Hyon Suk-
dc.contributor.alternativeNameLee, Min Geol-
dc.contributor.alternativeNameLee, Jong Han-
dc.contributor.affiliatedAuthorLee, Min Geol-
dc.contributor.affiliatedAuthorLee, Jong Han-
dc.contributor.affiliatedAuthorKim, Hyon Suk-
dc.rights.accessRightsnot free-
dc.citation.volume29-
dc.citation.number5-
dc.citation.startPage383-
dc.citation.endPage386-
dc.identifier.bibliographicCitationJOURNAL OF CLINICAL LABORATORY ANALYSIS, Vol.29(5) : 383-386, 2015-
dc.identifier.rimsid30910-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Dermatology (피부과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.