Direct Identification of Urinary Tract Pathogens From Urine Samples Using the Vitek MS System Based on Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry

DC Field Value Language
dc.contributor.author이경원-
dc.date.accessioned2016-02-04T11:22:07Z-
dc.date.available2016-02-04T11:22:07Z-
dc.date.issued2015-
dc.identifier.issn2234-3806-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/140269-
dc.description.abstractBACKGROUND: We evaluated the coincidence rate between Vitek MS system (bioMérieux, France) and Vitek 2 in identifying uropathogens directly from urine specimens. METHODS: Urine specimens submitted to our microbiology laboratory between July and September 2013 for Gram staining and bacterial culture were analyzed. Bacterial identification was performed by using the conventional method. Urine specimens showing a single morphotype by Gram staining were processed by culturing and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Of 2,370 urine specimens, 251 showed a single morphotype on Gram staining, and among them, 202 were available for MALDI-TOF MS. RESULTS: In these 202 specimens, colony growth was observed in 189 specimens, and 145 specimens had significant growth of single-colony morphotype in culture. One hundred and ten (75.9%) of them had colony counts of ≥10(5) colony-forming units (CFU)/mL and included 71 enteric gram-negative bacteria (GNB), 5 glucose-non-fermenting GNB, 9 gram-positive cocci (GPC), and 25 yeasts. Furthermore, 70 (98.6%), 3 (60.0%), 4 (44.4%), and 5 (20.0%), respectively, of these were correctly identified by Vitek MS. Thirty-one specimens (21.4%; 11 GNB, 7 GPC, 12 yeasts, and 1 gram-positive bacillus) had colony counts of 10(4)-10(5) CFU/mL. Four specimens (2.8%) yielded colony counts of 10(3)-10(4) CFU/mL. CONCLUSIONS: Vitek MS showed high rate of accuracy for the identification of GNB in urine specimens (≥10(5) CFU/mL). This could become a rapid and accurate diagnostic method for urinary tract infection caused by GNB. However, for the identification of GPC and yeasts, further studies on appropriate pre-treatment are warranted.-
dc.description.statementOfResponsibilityopen-
dc.format.extent416~422-
dc.relation.isPartOfANNALS OF LABORATORY MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHGentian Violet/chemistry-
dc.subject.MESHGram-Negative Bacteria/chemistry-
dc.subject.MESHGram-Negative Bacteria/isolation & purification-
dc.subject.MESHGram-Negative Bacteria/metabolism*-
dc.subject.MESHGram-Positive Cocci/chemistry-
dc.subject.MESHGram-Positive Cocci/isolation & purification-
dc.subject.MESHGram-Positive Cocci/metabolism*-
dc.subject.MESHHumans-
dc.subject.MESHPhenazines/chemistry-
dc.subject.MESHSaccharomyces cerevisiae/chemistry-
dc.subject.MESHSaccharomyces cerevisiae/isolation & purification-
dc.subject.MESHSaccharomyces cerevisiae/metabolism*-
dc.subject.MESHSpectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization*-
dc.subject.MESHUrinalysis-
dc.subject.MESHUrinary Tract Infections/diagnosis-
dc.subject.MESHUrinary Tract Infections/microbiology*-
dc.subject.MESHUrinary Tract Infections/urine-
dc.subject.MESHUrine/microbiology*-
dc.titleDirect Identification of Urinary Tract Pathogens From Urine Samples Using the Vitek MS System Based on Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthorYeongsic Kim-
dc.contributor.googleauthorKang Gyun Park-
dc.contributor.googleauthorKyungwon Lee-
dc.contributor.googleauthorYeon-Joon Park-
dc.identifier.doi10.3343/alm.2015.35.4.416-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02649-
dc.relation.journalcodeJ00164-
dc.identifier.eissn2234-3814-
dc.identifier.pmid26131413-
dc.subject.keywordMALDI-TOF MS-
dc.subject.keywordUTI-
dc.subject.keywordUrinary tract pathogens-
dc.subject.keywordVitek MS-
dc.contributor.alternativeNameLee, Kyung Won-
dc.contributor.affiliatedAuthorLee, Kyung Won-
dc.rights.accessRightsfree-
dc.citation.volume35-
dc.citation.number4-
dc.citation.startPage416-
dc.citation.endPage422-
dc.identifier.bibliographicCitationANNALS OF LABORATORY MEDICINE, Vol.35(4) : 416-422, 2015-
dc.identifier.rimsid50391-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.