dc.description.abstractBACKGROUND: We recently introduced an optical sensor, termed photothermal spectral-domain optical coherence reflectometer (PT SD-OCR), capable of direct measurement of hemoglobin concentration ([Hb]) without chemicals and pre-processing of blood. PT SD-OCR measures [Hb] by quantifying refractive index changes of blood samples due to photothermal effect under the irradiation of 532-nm light. We evaluated diagnostic accuracy and precision of PT SD-OCR in anemic patients. METHODS: We used PT SD-OCR to measure [Hb] in 50 anemic patients, and examined its accuracy against a hematology analyzer (ADVIA 2120i, Siemens AG). Its precision was assessed by examining the SD and CV based on 20 repeated measurements on 3 blood samples. Its performance was also compared with a hemoglobinometer (HemoCue 201+, HemoCue). RESULTS: The PT SD-OCR demonstrated good correspondence with the hematology analyzer with a Pearson's correlation coefficient of 0.992 and a bias of -0.055 g/dl. Standard deviation and CV were measured to be <0.25 g/dl and <2.05%. CONCLUSIONS: Simple and chemical-free operation of PT SD-OCR enabled rapid and accurate measurement of [Hb] in anemic patients. The sensor is expected to facilitate clinical procedures related to blood-related disorders in patient care.-
dc.description.statementOfResponsibilityopen-
dc.format.extent71~76-
dc.relation.isPartOfCLINICA CHIMICA ACTA-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAnemia/blood*-
dc.subject.MESHHemoglobins/analysis*-
dc.subject.MESHHumans-
dc.subject.MESHThermography*-
dc.subject.MESHTomography, Optical Coherence*-
dc.titleHemoglobin assay in anemic patients with a photothermal spectral-domain optical coherence reflectometric sensor-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthorHun Kim-
dc.contributor.googleauthorSungwook Song-
dc.contributor.googleauthorJinyeong Yim-
dc.contributor.googleauthorHyun Ok Kim-
dc.contributor.googleauthorChulmin Joo-
dc.identifier.doi10.1016/j.cca.2014.10.001-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01122-
dc.relation.journalcodeJ00543-
dc.identifier.eissn1873-3492-
dc.identifier.pmid25312865-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S000989811400432X-
dc.subject.keywordAnemia-
dc.subject.keywordHemoglobin concentration-
dc.subject.keywordOptical interferometer-
dc.subject.keywordOptical sensor-
dc.subject.keywordPhotothermal effect-
dc.contributor.alternativeNameKim, Hyun Ok-
dc.contributor.affiliatedAuthorKim, Hyun Ok-
dc.rights.accessRightsnot free-
dc.citation.volume439-
dc.citation.startPage71-
dc.citation.endPage76-
dc.identifier.bibliographicCitationCLINICA CHIMICA ACTA, Vol.439 : 71-76, 2015-
dc.identifier.rimsid45512-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.