Complications of the Intramedullary Skeletal Kinetic Distractor (ISKD) in distraction osteogenesis.

DC Field Value Language
dc.contributor.author이동훈-
dc.date.accessioned2015-12-28T10:55:23Z-
dc.date.available2015-12-28T10:55:23Z-
dc.date.issued2014-
dc.identifier.issn0009-921X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/138314-
dc.description.abstractBACKGROUND: The Intramedullary Skeletal Kinetic Distractor (ISKD) (Orthofix Inc, Lewisville, TX, USA) is an intramedullary device designed for more comfortable limb lengthening than that with external fixators; lengthening is achieved with this nail using rotational oscillation between two telescoping sections. However, the degree to which this device achieves this goal and its complication rate have not been fully documented. QUESTIONS/PURPOSES: We determined (1) the frequency with which distraction was not achieved at the desired rate, (2) whether pain differed between patients with normally and abnormally distracting nails, (3) risk factors for abnormal nails, and (4) other complications. METHODS: We analyzed 35 lengthening segments (26 femurs, nine tibias) in 19 patients. Mean length achieved was 47 mm. Femoral nails were categorized into four groups according to distraction rate: normal, runaway (unintentionally faster rate [> 1.5 mm/day]), difficult-to-distract (slower rate [< 0.8 mm/day] requiring manual manipulation but not requiring general anesthesia), and nondistracting (slower rate [< 0.8 mm/day] requiring manual manipulation under general anesthesia or reosteotomy). Possible risk factors, including age, BMI, preoperative thigh circumferences, degree of intramedullary overreaming, and length of the thicker portion of the nail within the distal fragment, were compared among groups. VAS pain scores were compared among groups under three conditions: rest, physiotherapy, and distraction motion. Complications were also analyzed. Minimum followup was 15 months (mean, 26 months; range, 15-38 months) after first-stage surgery. RESULTS: Abnormal distraction rate was observed in 21 of 35 segments (60%; 17 femurs, four tibias). VAS pain scores showed no differences among groups during rest or physiotherapy but were higher (p = 0.02) in the problematic nails (7-8 points) versus normal nails (3 points) during distraction. Only mean length of the thicker portion of the nail within the distal fragment differed between normally and abnormally distracting nails (95 mm versus 100 mm; p = 0.03), although this was unlikely to be clinically important. Complications occurred in 10 patients (53%), including five with decreased ankle ROM during distraction, four with delayed bone healing, and one with mechanical device failure during distraction. CONCLUSIONS: Rate control was difficult to achieve with the ISKD nail for femoral and tibial lengthenings, complications were relatively common, and among patients in whom rate control was not achieved, pain levels were high. Based on our findings, we believe that surgeons should avoid use of this nail. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.-
dc.description.statementOfResponsibilityopen-
dc.format.extent3852~3859-
dc.relation.isPartOfCLINICAL ORTHOPAEDICS AND RELATED RESEARCH-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAnkle Joint/physiopathology-
dc.subject.MESHBiomechanical Phenomena-
dc.subject.MESHBone Nails/adverse effects*-
dc.subject.MESHFemale-
dc.subject.MESHFemur/diagnostic imaging-
dc.subject.MESHFemur/physiopathology-
dc.subject.MESHFemur/surgery*-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHOsteogenesis, Distraction/adverse effects*-
dc.subject.MESHOsteogenesis, Distraction/instrumentation*-
dc.subject.MESHPain Measurement-
dc.subject.MESHPain, Postoperative/diagnosis-
dc.subject.MESHPain, Postoperative/etiology*-
dc.subject.MESHProsthesis Design-
dc.subject.MESHProsthesis Failure*-
dc.subject.MESHRadiography-
dc.subject.MESHRange of Motion, Articular-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHRisk Factors-
dc.subject.MESHTibia/diagnostic imaging-
dc.subject.MESHTibia/physiopathology-
dc.subject.MESHTibia/surgery*-
dc.subject.MESHTime Factors-
dc.subject.MESHTreatment Outcome-
dc.subject.MESHYoung Adult-
dc.titleComplications of the Intramedullary Skeletal Kinetic Distractor (ISKD) in distraction osteogenesis.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학)-
dc.contributor.googleauthorDong Hoon Lee-
dc.contributor.googleauthorKeun Jung Ryu-
dc.contributor.googleauthorHae Ryong Song-
dc.contributor.googleauthorSoo Hong Han-
dc.identifier.doi10.1007/s11999-014-3547-4-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02741-
dc.relation.journalcodeJ00602-
dc.identifier.eissn1528-1132-
dc.identifier.pmid24604112-
dc.identifier.urlhttp://link.springer.com/article/10.1007/s11999-014-3547-4-
dc.contributor.alternativeNameLee, Dong Hoon-
dc.contributor.affiliatedAuthorLee, Dong Hoon-
dc.rights.accessRightsfree-
dc.citation.volume472-
dc.citation.number12-
dc.citation.startPage3852-
dc.citation.endPage3859-
dc.identifier.bibliographicCitationCLINICAL ORTHOPAEDICS AND RELATED RESEARCH, Vol.472(12) : 3852-3859, 2014-
dc.identifier.rimsid52800-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers

qrcode