Cited 8 times in
Changes in jugular bulb oxygen saturation during off-pump coronary artery bypass graft surgery
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 곽영란 | - |
dc.contributor.author | 김승호 | - |
dc.contributor.author | 오영준 | - |
dc.contributor.author | 유경종 | - |
dc.contributor.author | 홍용우 | - |
dc.date.accessioned | 2015-08-26T16:35:23Z | - |
dc.date.available | 2015-08-26T16:35:23Z | - |
dc.date.issued | 2005 | - |
dc.identifier.issn | 0001-5172 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/114751 | - |
dc.description.abstract | Background: The effect of haemodynamic derangement during coronary artery anastomosis in off-pump coronary artery bypass surgery on cerebral blood flow has not been elucidated. Jugular bulb oxygen saturation is a useful indicator of cerebral blood flow provided that the cerebral metabolic rate is constant. This study was designed to evaluate the changes in jugular bulb oxygen saturation during off-pump coronary artery bypass surgery. Methods: With IRB approval, 48 patients were included. After anaesthesia, an 18-G catheter was introduced into the jugular bulb. Haemodynamic variables and oxygen profiles from gas analysis of jugular bulb blood and arterial blood were obtained: after sternotomy (baseline); at 5 min after the beginning of the anastomosis of the left anterior descending artery, obtuse marginal artery, and right coronary artery; and after sternal closure. Results: Cardiac index and mixed venous oxygen saturation decreased significantly during anastomosis of all three arteries compared to the baseline value. Although the changes in jugular bulb oxygen saturation during anastomosis were statistically significant compared to its baseline value, jugular bulb oxygen saturation remained within normal limit throughout the study. Conclusions: Jugular bulb oxygen saturation, which represents the global cerebral oxygenation, was well maintained during the anastomosis of all coronary arteries despite significant haemodynamic changes during off-pump coronary artery bypass (OPCAB). | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 956~961 | - |
dc.relation.isPartOf | ACTA ANAESTHESIOLOGICA SCANDINAVICA | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Carbon Dioxide/blood | - |
dc.subject.MESH | Cardiopulmonary Bypass | - |
dc.subject.MESH | Cerebrovascular Circulation* | - |
dc.subject.MESH | Coronary Artery Bypass* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Jugular Veins/metabolism* | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Oxygen/blood* | - |
dc.title | Changes in jugular bulb oxygen saturation during off-pump coronary artery bypass graft surgery | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Anesthesiology (마취통증의학) | - |
dc.contributor.googleauthor | J. Y. Kim | - |
dc.contributor.googleauthor | Y. L. Kwak | - |
dc.contributor.googleauthor | Y. W. Hong | - |
dc.contributor.googleauthor | K. J. Yoo | - |
dc.contributor.googleauthor | S. H. Kim | - |
dc.contributor.googleauthor | Y. J. Oh | - |
dc.identifier.doi | 10.1111/j.1399-6576.2005.00739.x | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00172 | - |
dc.contributor.localId | A02389 | - |
dc.contributor.localId | A02453 | - |
dc.contributor.localId | A04420 | - |
dc.contributor.localId | A00666 | - |
dc.relation.journalcode | J00006 | - |
dc.identifier.eissn | 1399-6576 | - |
dc.identifier.pmid | 16045656 | - |
dc.identifier.url | http://onlinelibrary.wiley.com/doi/10.1111/j.1399-6576.2005.00739.x/abstract | - |
dc.subject.keyword | Jugular bulb oxygen saturation | - |
dc.subject.keyword | off-pump coronary artery bypass | - |
dc.subject.keyword | brain ischemia | - |
dc.contributor.alternativeName | Kwak, Young Lan | - |
dc.contributor.alternativeName | Kim, Seung Ho | - |
dc.contributor.alternativeName | Oh, Young Jun | - |
dc.contributor.alternativeName | Yoo, Kyung Jong | - |
dc.contributor.alternativeName | Hong, Yong Woo | - |
dc.contributor.affiliatedAuthor | Kwak, Young Lan | - |
dc.contributor.affiliatedAuthor | Oh, Young Jun | - |
dc.contributor.affiliatedAuthor | Yoo, Kyung Jong | - |
dc.contributor.affiliatedAuthor | Hong, Yong Woo | - |
dc.contributor.affiliatedAuthor | Kim, Seung Ho | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 49 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 956 | - |
dc.citation.endPage | 961 | - |
dc.identifier.bibliographicCitation | ACTA ANAESTHESIOLOGICA SCANDINAVICA, Vol.49(7) : 956-961, 2005 | - |
dc.identifier.rimsid | 46097 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.