0 431

Cited 0 times in

Removal of the Broken Tip of a Hexagonal Screwdriver From a Nail End Cap Using a Magnetic Bar

DC Field Value Language
dc.contributor.author양규현-
dc.date.accessioned2015-07-15T17:05:41Z-
dc.date.available2015-07-15T17:05:41Z-
dc.date.issued2003-
dc.identifier.issn0890-5339-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/114214-
dc.description.abstractThe tip of the hexagonal screwdriver can be broken and retained in the recess of the end cap of an intramedullary nail. It can happen when the position of the patient's limb suddenly changes during the tightening procedure. Removal of the broken tip is necessary due to metal incompatibility and for the potential of a future procedure. A simple solution for this problem is presented, the use of a magnetic bar normally used for removal of orbital metallic foreign bodies.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfJOURNAL OF ORTHOPAEDIC TRAUMA-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHBone Nails*-
dc.subject.MESHDevice Removal-
dc.subject.MESHEquipment Failure-
dc.subject.MESHForeign Bodies-
dc.subject.MESHFractures, Malunited/surgery*-
dc.subject.MESHHumans-
dc.subject.MESHIntraoperative Complications*-
dc.subject.MESHMagnetics/therapeutic use*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHTibial Fractures/surgery*-
dc.titleRemoval of the Broken Tip of a Hexagonal Screwdriver From a Nail End Cap Using a Magnetic Bar-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학)-
dc.contributor.googleauthorKyu Hyun Yang-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02282-
dc.relation.journalcodeJ01673-
dc.identifier.eissn1531-2291-
dc.identifier.pmid14574192-
dc.identifier.urlhttp://ovidsp.ovid.com/ovidweb.cgi?T=JS&CSC=Y&NEWS=N&PAGE=fulltext&AN=00005131-200310000-00007&LSLINK=80&D=ovft-
dc.subject.keywordfracture-
dc.subject.keywordhexagonal screwdriver-
dc.subject.keywordmagnet-
dc.contributor.alternativeNameYang, Kyu Hyun-
dc.contributor.affiliatedAuthorYang, Kyu Hyun-
dc.rights.accessRightsnot free-
dc.citation.volume17-
dc.citation.number9-
dc.citation.startPage642-
dc.citation.endPage643-
dc.identifier.bibliographicCitationJOURNAL OF ORTHOPAEDIC TRAUMA, Vol.17(9) : 642-643, 2003-
dc.identifier.rimsid52083-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.