321 590

Cited 0 times in

Cited 0 times in

미만성 스텐트 내 재협착에 대한 Cutting Balloon 관동맥 성형술과 Holmium 풍선도자를 이용한 방사선 근접치료

DC Field Value Language
dc.contributor.author장양수-
dc.date.accessioned2015-07-15T17:04:42Z-
dc.date.available2015-07-15T17:04:42Z-
dc.date.issued2003-
dc.identifier.issn1738-5520-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/114181-
dc.description.abstractBackground and Objectives : A cutting balloon angioplasty for the treatment of diffuse in-stent restenosis has been reported to be superior to conventional percutaneous transluminal coronary angioplasty. Intracoronary radiation therapy is also a novel technique for preventing a recurrence of in-stent restenosis following percutaneous coronary intervention. Holmium (166Ho) is a high-energy β-emitter, which is available in liquid form. We performed a cutting balloon angioplasty, with subsequent intracoronary 166Ho brachytherapy, for the treatment of in-stent restenosis. Subjects and Methods : Fifty two patients, with in-stent restenosis, were treated with cutting balloon angioplasty and intracoronary 166Ho brachytherapy. For the irradiation, a balloon approximately 10 mm longer than the stent was used. Radiation doses of 18 Gy at a depth of 1 mm from balloon-artery interface were used. A quantitative coronary angiography was performed during the procedure and at the 6-month follow-up. The patients were followed clinically for an average of 16.8±9.8 months. Results : The procedures were successful in all patients. The minimal luminal diameter of in-stent restenosis lesions, initially and after treatment, and the lesion length were 0.58±0.30 and 2.55±0.29 mm, and 20.7±7.1 mm, respectively. Thirty four (65.4%) patients completed the angiographic follow-up at 6 months. The minimal luminal diameter of lesion and late loss were 2.03±0.83 and 0.57±0.79 mm, respectively. The target lesion restenosis rate was 14.7%. No patients presented with MACE, such as MI, death or stent thrombosis. Conclusion : The combination of cutting balloon angioplasty and intracoronary 166Ho brachytherapy was feasible, safe and effective for the treatment of diffuse in-stent restenosis.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfKOREAN CIRCULATION JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHIn-stent restenosis;Cutting balloon angioplasty;Intracoronary 166Ho brachytherapy-
dc.title미만성 스텐트 내 재협착에 대한 Cutting Balloon 관동맥 성형술과 Holmium 풍선도자를 이용한 방사선 근접치료-
dc.title.alternativeTreatment of Diffuse in-stent Restenosis Combined with Cutting Balloon Angioplasty and intracoronary holmium Brachytherapy-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학)-
dc.contributor.googleauthor강웅철-
dc.contributor.googleauthor변영섭-
dc.contributor.googleauthor조승연-
dc.contributor.googleauthor심원흠-
dc.contributor.googleauthor이종두-
dc.contributor.googleauthor장양수-
dc.contributor.googleauthor윤영원-
dc.contributor.googleauthor구본권-
dc.contributor.googleauthor박성하-
dc.contributor.googleauthor고영국-
dc.contributor.googleauthor최동훈-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03448-
dc.relation.journalcodeJ01953-
dc.identifier.eissn1738-5555-
dc.subject.keywordIn-stent restenosis;Cutting balloon angioplasty;Intracoronary 166Ho brachytherapy-
dc.contributor.alternativeNameJang, Yang Soo-
dc.contributor.affiliatedAuthorJang, Yang Soo-
dc.rights.accessRightsfree-
dc.citation.volume33-
dc.citation.number8-
dc.citation.startPage671-
dc.citation.endPage679-
dc.identifier.bibliographicCitationKOREAN CIRCULATION JOURNAL, Vol.33(8) : 671-679, 2003-
dc.identifier.rimsid52055-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.