ICG 청정검사에 있어서 고식적 정맥채혈 방법과 finger monitoring 방법 간의 비교

DC Field Value Language
dc.contributor.author김정호-
dc.date.accessioned2015-07-15T16:43:24Z-
dc.date.available2015-07-15T16:43:24Z-
dc.date.issued2003-
dc.identifier.issn1598-6535-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/113469-
dc.description.abstractBackground :The indocyanine green (ICG) finger monitoring method is a newly developed noninvasive method for the ICG clearance test. This study was performed to determine its clinical usefulness compared with the conventional blood sampling method. Method :The ICG clearance test was performed on 270 patients using both the conventional blood sampling method and the finger monitoring method simultaneously. The plasma disappearance rate of the ICG and the 15-minute retention ratio (ICG R15) were analyzed and compared with the conventional blood sampling method. Result :The plasma disappearance rate using the finger monitoring method was slightly lower than that of the conventional blood sampling method with good correlation (r=0.840, P<0.001). Conclusion :As there was a good correlation between the conventional blood sampling method and the finger monitoring method, the latter method seemed to be clinically useful due to its convenience and accuracy.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfKOREAN JOURNAL OF LABORATORY MEDICINE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHICG clearance test-
dc.subject.MESHFinger monitoring method-
dc.subject.MESHPlasma disappearance rate-
dc.subject.MESH15- minute retention ratio-
dc.titleICG 청정검사에 있어서 고식적 정맥채혈 방법과 finger monitoring 방법 간의 비교-
dc.title.alternativeComparison of the Indocyanine Green Clearance Test Using Conventional Blood Sampling and Finger Monitoring Methods-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthor김신영-
dc.contributor.googleauthor박노진-
dc.contributor.googleauthor권오헌-
dc.contributor.googleauthor김정호-
dc.contributor.googleauthor이경률-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00903-
dc.relation.journalcodeJ02045-
dc.subject.keywordICG clearance test-
dc.subject.keywordFinger monitoring method-
dc.subject.keywordPlasma disappearance rate-
dc.subject.keyword15- minute retention ratio-
dc.contributor.alternativeNameKim, Jeong Ho-
dc.contributor.affiliatedAuthorKim, Jeong Ho-
dc.rights.accessRightsfree-
dc.citation.volume23-
dc.citation.number2-
dc.citation.startPage88-
dc.citation.endPage91-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF LABORATORY MEDICINE, Vol.23(2) : 88-91, 2003-
dc.identifier.rimsid49287-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.