564 520

Cited 0 times in

Ti-Ag 합금의 인공타액 내에서의 전기화학적 특성

DC Field Value Language
dc.contributor.author김경남-
dc.date.accessioned2015-07-14T17:20:00Z-
dc.date.available2015-07-14T17:20:00Z-
dc.date.issued2003-
dc.identifier.issn1225-1631-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/112670-
dc.description.abstractTitanium and its alloys are widely used in biomedical, and dental fields: because of their excellent corrosion resistance, biocompatibility, high strength to weight ratio and good fatigue properties. It is well known that titanium is protected from corrosion due to the stability of passive film that controls and determines the corrosion resistance of titanium. The stability of passive film can also determine biocompatibility of titanium and its alloys. The purpose of this study was to evaluate the electrochemical properties of Ti-Ag alloys and the stability of passive film in artificial saliva. We designed Ti-Ag alloys with silver contents ranging from zero to 5.0 at% in steps of 0.5 at%. The alloys were arc-melted, homogenized, hot-rolled to 2 mm in thickness, and finally solution heat-treated for I hour and quenched in water. Potentiodynamic and potentiostatic testing were performed and open circuit potential of the Ti-Ag alloys was measured in artificial saliva 3, Passive film of the Ti-Ag alloys was analyzed by XPS(x-ray photoelectron spectroscopy). - Ti Ag alloys showed low-passive current density and electrochemically stable behavior in the artificial saliva and passive film of the Ti-Ag alloys was composed of TiO2, Ti203 and TiO. As Ag content mc`.iz~ased, TiO2 fraction increased and titanium oxide layer of the Ti-Ag, alloys formed thicker than that of titanium.lt is thought that Ti-Ag alloys can be adopted and used safely with good biocompatibility for dental application-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfJournal of the Korean Research Society for Dental Materials (대한치과기재학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleTi-Ag 합금의 인공타액 내에서의 전기화학적 특성-
dc.title.alternativeElectrochemical Properties of Ti-Ag Alloys in Artificial Salica-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Dental Engineering (치과생체재료공학)-
dc.contributor.googleauthor심형민-
dc.contributor.googleauthor오근택-
dc.contributor.googleauthor김경남-
dc.identifier.doiOAK-2004-01278-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00292-
dc.relation.journalcodeJ01846-
dc.subject.keywordbiocompatibility-
dc.subject.keywordelectrochemical properties-
dc.subject.keywordpassive film-
dc.subject.keywordTi-Ag alloys-
dc.contributor.alternativeNameKim, Kyoung Nam-
dc.contributor.affiliatedAuthorKim, Kyoung Nam-
dc.rights.accessRightsfree-
dc.citation.volume30-
dc.citation.number4-
dc.citation.startPage365-
dc.citation.endPage372-
dc.identifier.bibliographicCitationJournal of the Korean Research Society for Dental Materials (대한치과기재학회지), Vol.30(4) : 365-372, 2003-
dc.identifier.rimsid42607-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.