2119 587

Cited 0 times in

코성형술에 사용된 고어텍스의 안정성에 관한 다기관 평가

DC Field Value Language
dc.contributor.author김경수-
dc.date.accessioned2015-07-14T17:09:53Z-
dc.date.available2015-07-14T17:09:53Z-
dc.date.issued2004-
dc.identifier.issn1225-035X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/112335-
dc.description.abstractBackground and Objectives: This study was done to evaluate the safety of Gore-Tex as a nasal implant. Materials and Method: A retrospective multicenter study was carried out on 15 surgeons from 11 general hospitals and 4 private practice clinics regarding the safety of the Gore-Tex as a nasal implant. The study involved 853 patients, of whom 656 received primary surgery and 197 revision surgery. Gore-Tex was mainly used as a dorsal implant in a form of sheet or as a reinforced nasal implant. Results: The overall complication rate associated with Gore-Tex was 2.5% (21 cases). Infection was the most common complication (18 cases ; 2.1%) followed by 2 cases of seroma and 1 case of persistent nasal swelling. In 19 out of 21 complication cases, the graft needed removal to control the infection or seroma (91% removal rate). Nine cases of infection developed in both primary cases (1.37%) and in revision cases (4.57%), which suggests a higher association rate between infection and revision cases (p=0.0062). Infection developed within 1 month in 5 cases while 9 cases developed infection after 6months of operation. Other complications such as aesthetic problems (malpositioning of the implant or dorsal irregularities) were found in 15 cases (1.8%) and hematoma in 1 case. Conclusion: The infection rate of Gore-Tex used in rhinoplasty was about 2% and it rose significantly in the revision cases. If infected, almost all of the implanted Gore-Tex needs removal; therefore, we suggest judicious use of Gore-Tex in rhinoplasty.-
dc.description.statementOfResponsibilityopen-
dc.format.extent1251~1255-
dc.relation.isPartOfKorean Journal of Otolaryngology (대한이비인후과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title코성형술에 사용된 고어텍스의 안정성에 관한 다기관 평가-
dc.title.alternativeMulticenter Evaluation on the Safety of Gore-Tex as an Implant in Rhinoplasty-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Otorhinolaryngology (이비인후과학)-
dc.contributor.googleauthor진홍률-
dc.contributor.googleauthor이주연-
dc.contributor.googleauthor연제엽-
dc.contributor.googleauthor이재서-
dc.contributor.googleauthor이상학-
dc.contributor.googleauthor윤주헌-
dc.contributor.googleauthor윤자복-
dc.contributor.googleauthor윤영석-
dc.contributor.googleauthor박효진-
dc.contributor.googleauthor박동준-
dc.contributor.googleauthor문형진-
dc.contributor.googleauthor동헌종-
dc.contributor.googleauthor노환중-
dc.contributor.googleauthor김춘동-
dc.contributor.googleauthor김영기-
dc.contributor.googleauthor김경수-
dc.contributor.googleauthor강제구-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.relation.journalcodeJ02088-
dc.subject.keywordGore-Tex-
dc.subject.keywordRhinoplasty-
dc.subject.keywordInfection-
dc.contributor.alternativeNameKim, Kyung Su-
dc.rights.accessRightsfree-
dc.citation.volume47-
dc.citation.number12-
dc.citation.startPage1251-
dc.citation.endPage1255-
dc.identifier.bibliographicCitationKorean Journal of Otolaryngology (대한이비인후과학회지), Vol.47(12) : 1251-1255, 2004-
dc.identifier.rimsid36250-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Otorhinolaryngology (이비인후과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.