Cited 0 times in
정밀 방사선치료
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이창걸 | - |
dc.date.accessioned | 2015-07-14T17:07:38Z | - |
dc.date.available | 2015-07-14T17:07:38Z | - |
dc.date.issued | 2004 | - |
dc.identifier.issn | 1975-8456 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/112261 | - |
dc.description.abstract | The technical advances that have been achieved over the last decade in the area of 3-dimensional radiotherapy treatment planning capabilities and new and more flexible hardware capabilities, such as computer-controlled treatments, multileaf collimators, and real-time portal imaging devices, have brought about 3-dimensional conformal radiation therapy. For the purpose of highly conformal radiation therapy, a variety of radiation treatment techniques and treatment machines such as stereotactic radiosurgery(SRS) using gamma-knife, stereotactic radiotherapy(SRT) using linear accelerator, and stereotactic whole body radiotherapy have been invented. Intensity-modulated radiation therapy(IMRT) is a new and evolving technological advance in high-precision radiation therapy. It is an extension of 3-dimensional conformal radiotherapy(3-DCRT) that allows the delivery of highly complex isodose profiles to the target, while minimizing radiation exposure to surrounding normal tissues. Image-guided adaptive radiotherapy(IGRT) combines scanning and radiation equipment, to provide images of the patient's organs in the treatment position, at the time of the treatment, optimizing the accuracy and precision of the radiotherapy. Respiratory-gated radiotherapy was developed to overcome the motion of organs. Most high precision radiation therapy approaches increase the time and efforts required by physicians and physicists, because optimization systems are not yet robust enough to provide automated solutions for all disease sites, and routine QA testing is still quite time-consuming. Preliminary clinical experiences of high precision radiation therapy have been encouraging by high rates of local control and decrease of toxicity. This article provides an overview of high precision radiotherapy such as 3-DCRT, SRS, SRT, Cyberknife, IMRT, and IGRT. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 663~671 | - |
dc.language | JOURNAL OF THE KOREAN MEDICAL ASSOCIATION | - |
dc.publisher | JOURNAL OF THE KOREAN MEDICAL ASSOCIATION | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN MEDICAL ASSOCIATION | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 정밀 방사선치료 | - |
dc.title.alternative | High Precision Radiotherapy | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Radiation Oncology (방사선종양학) | - |
dc.contributor.googleauthor | 이창걸 | - |
dc.identifier.doi | 10.5124/jkma.2004.47.7.663 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.relation.journalcode | J01833 | - |
dc.identifier.eissn | 2093-5951 | - |
dc.subject.keyword | Radiotherapy | - |
dc.subject.keyword | 3-dimensional conformal RT | - |
dc.subject.keyword | IMRT | - |
dc.subject.keyword | Stereotactic radiosurgery | - |
dc.contributor.alternativeName | Lee, Chang Geol | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 47 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 663 | - |
dc.citation.endPage | 671 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, Vol.47(7) : 663-671, 2004 | - |
dc.identifier.rimsid | 38008 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.