624 421

Cited 0 times in

수산화 인회석이 피복된 해부학형 Profile® 대퇴삽입물을 이용한 인공 고관절 치환술의 결과 : 5년에서 10년 추시 결과

DC Field Value Language
dc.contributor.author양익환-
dc.contributor.author한창동-
dc.date.accessioned2015-07-14T17:02:02Z-
dc.date.available2015-07-14T17:02:02Z-
dc.date.issued2004-
dc.identifier.issn1226-2102-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/112072-
dc.description.abstractPURPOSE: To report the results of hip arthroplasty using an uncemented hydroxyapatite (HA) coated anatomical Profile(R) femoral stem during a follow-up period of five to ten years. MATERIALS AND METHODS: Eighty-eight patients, ninety-nine cases of hip arthroplasty, who underwent surgery from May 1993 to February 1998, were reviewed clinically and radiographically. RESULTS: The mean Harris hip rating score was 54.4 preoperatively, which improved to 88.2 at the last follow up postoperatively. The radiographic evaluations revealed that endosteal new bone formation developed at Gruen zone 1 and 7 in all cases (100%) between 6 month and one year after surgery. Approximately 20 cases (20%) showed proximal osteoporosis due to profound stress shielding, and 83 cases (83.8%) showed distal cortical hypertrophy (zone 2, 6). These femoral remodelings correlated with the clinical results statistically. There was no aseptic loosening, but the polyethylene liner was changed only in one hip due to severe liner wear. CONCLUSION: This study indicate that the anatomical Profile(R) femoral stem can provide excellent initial stability and osseointegration. However, profound proximal bone loss was noted secondary to distal cortical hypertrophy in the long-term follow up. Therefore, other design concepts are needed, in which the femoral strain transfers more proximally rather than distally.-
dc.description.statementOfResponsibilityopen-
dc.format.extent654~661-
dc.relation.isPartOfJournal of the Korean Orthopaedic Association (대한정형외과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title수산화 인회석이 피복된 해부학형 Profile® 대퇴삽입물을 이용한 인공 고관절 치환술의 결과 : 5년에서 10년 추시 결과-
dc.title.alternativeThe Results of Hip Arthroplasty with Hydroxyapatite Coated Anatomical Profile® Femoral Stem - Result After 5-Years to 10-years Follow up --
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학)-
dc.contributor.googleauthor한창동-
dc.contributor.googleauthor김호중-
dc.contributor.googleauthor양익환-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.relation.journalcodeJ01839-
dc.subject.keywordHip arthroplasty-
dc.subject.keywordProfile femoral stem-
dc.subject.keywordHA coating-
dc.subject.keywordStress shielding-
dc.subject.keywordCortical hypertrophy-
dc.contributor.alternativeNameYang, Ick Hwan-
dc.contributor.alternativeNameHan, Chang Dong-
dc.rights.accessRightsfree-
dc.citation.volume39-
dc.citation.number6-
dc.citation.startPage654-
dc.citation.endPage661-
dc.identifier.bibliographicCitationJournal of the Korean Orthopaedic Association (대한정형외과학회지), Vol.39(6) : 654-661, 2004-
dc.identifier.rimsid52930-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.