Cited 0 times in
대퇴골 전자간 불안정 골절에서 활강 지연 나사의 전후방 경사와 안정성과의 관계
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 양규현 | - |
dc.contributor.author | 원정훈 | - |
dc.contributor.author | 유제현 | - |
dc.contributor.author | 이동주 | - |
dc.date.accessioned | 2015-07-14T16:57:21Z | - |
dc.date.available | 2015-07-14T16:57:21Z | - |
dc.date.issued | 2004 | - |
dc.identifier.issn | 1225-1682 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/111918 | - |
dc.description.abstract | Purpose : To investigate the characteristics of the sliding pattern of the proximal fragment(head and neck) in unstable intertrochanteric fractures, which were fixed with a dynamic hip screw(DHS) with anterior to posterior or posterior to anterior insertion angle in the axial view. Materials and Methods : AO type A2.1 intertrochanteric fracture was reproduced in 10 proximal femur model (Synbone, Malans, Switzerland). Five fractured models were reduced and fixed using DHS with anterior to posterior insertion angle (group 1) and five models were fixed with posterior to anterior angle (group 2). Load of 500 N (30 cycles) was applied to the fracture fragment-plate complex using lnstron 6022. Data on the distance of sliding and the angle of rotation of the proximal fragment were collected and analyzed. Results : No significant difference was noted statistically in the distance of sliding between the two groups (p=0.92). However, the mean angle of rotation was 13.4° and 8.0° in group 1 and 2, respectively and the difference was statistically significant (p=0.012). Anterior cortical fracture of distal fragment was noted in 3 cases of group 1. There was no fracture of the anterior cortex in group 2. Conclusion : In unstable intertrochanteric fracture, the insertion angle of the lag screw in axial view does seem to play a role in the fate of bone-plate complex. Early eccentric contact of both fragments caused rotation of the proximal fragment in all cases and anterior cortical fracture of the distal fragment in 3 cases of group 1. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 308~313 | - |
dc.language | Journal of the Korean Fracture Society | - |
dc.publisher | Journal of the Korean Fracture Society | - |
dc.relation.isPartOf | Journal of the Korean Fracture Society | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 대퇴골 전자간 불안정 골절에서 활강 지연 나사의 전후방 경사와 안정성과의 관계 | - |
dc.title.alternative | Correlation between Anterior and Posterior Obliquity of the Sliding Lag Screw and Stability in Unstable Intertrochanteric Fractures | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Orthopedic Surgery (정형외과학) | - |
dc.contributor.googleauthor | 양규현 | - |
dc.contributor.googleauthor | 유제현 | - |
dc.contributor.googleauthor | 심동식 | - |
dc.contributor.googleauthor | 김대야 | - |
dc.contributor.googleauthor | 원정훈 | - |
dc.contributor.googleauthor | 이동주 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.relation.journalcode | J01824 | - |
dc.identifier.eissn | 2287-9293 | - |
dc.subject.keyword | Femur | - |
dc.subject.keyword | Intertrochanteric fracture | - |
dc.subject.keyword | Dynamic hip screw | - |
dc.subject.keyword | Insertion angle | - |
dc.contributor.alternativeName | Yang, Kyu Hyun | - |
dc.contributor.alternativeName | Won, Jung Hoon | - |
dc.contributor.alternativeName | Yoo, Je Hyun | - |
dc.contributor.alternativeName | Rhee, Dong Joo | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 17 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 308 | - |
dc.citation.endPage | 313 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Fracture Society, Vol.17(4) : 308-313, 2004 | - |
dc.identifier.rimsid | 53514 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.