Cited 0 times in
간이식 수술 환자에서 폐동맥 카테터 및 식도도플러로측정한 혈역학적 지표들의 비교
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 윤경봉 | - |
dc.contributor.author | 구본녀 | - |
dc.contributor.author | 남순호 | - |
dc.contributor.author | 반소영 | - |
dc.contributor.author | 배선준 | - |
dc.date.accessioned | 2015-07-14T16:52:30Z | - |
dc.date.available | 2015-07-14T16:52:30Z | - |
dc.date.issued | 2004 | - |
dc.identifier.issn | 2005-6419 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/111761 | - |
dc.description.abstract | BACKGROUND: The measurement of cardiac output is an essential part of anesthetic practice in patients undergoing liver transplantation. A thermodilution technique, using a pulmonary artery catheter is currently accepted as the gold standard in clinical practise. However, its use is associated with several limitations. METHODS: An esophageal doppler monitor was compared with the thermodilution technique in 22 patients undergoing split graft transplantation from a living donor. Six measurement were taken during liver transplantation, 1) control, 2) dissection phase, 3) anhepatic phase, 4) reperfusion phase, 5) after hepatic artery anastomosis, and 6) end of surgery. RESULTS: Significant difference were observed between the two measurement at all times studied with a strong correlation, except at the end of surgery (r > 0.4). CONCLUSIONS: The use of esophageal doppler monitor results in cardiac output measurements which are considerably different from those obtained using thermodilution, but a strong correlation exists between two methods. Thus the use of esohageal monitoring can be recommended in patients undergoing liver transplantation for trend monitoring. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 211~215 | - |
dc.relation.isPartOf | KOREAN JOURNAL OF ANESTHESIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 간이식 수술 환자에서 폐동맥 카테터 및 식도도플러로측정한 혈역학적 지표들의 비교 | - |
dc.title.alternative | Comparison of Hemodynamic Data obtained from a Pulmonary Artery Catheter vs. Esophageal Doppler during Liver Transplantation | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Anesthesiology (마취통증의학) | - |
dc.contributor.googleauthor | 구본녀 | - |
dc.contributor.googleauthor | 김종엽 | - |
dc.contributor.googleauthor | 남순호 | - |
dc.contributor.googleauthor | 이종호 | - |
dc.contributor.googleauthor | 반소영 | - |
dc.contributor.googleauthor | 배선준 | - |
dc.contributor.googleauthor | 윤경봉 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.relation.journalcode | J03189 | - |
dc.identifier.eissn | 2005-7563 | - |
dc.subject.keyword | cardiac output | - |
dc.subject.keyword | esophageal doppler monitor | - |
dc.subject.keyword | liver transplantation | - |
dc.subject.keyword | pulmonary artery catheter | - |
dc.contributor.alternativeName | Yoon, Kyoung Bong | - |
dc.contributor.alternativeName | Ku, Bon Nyo | - |
dc.contributor.alternativeName | Nam, Soon Ho | - |
dc.contributor.alternativeName | Ban, So Young | - |
dc.contributor.alternativeName | Bai, Sun Joon | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 47 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 211 | - |
dc.citation.endPage | 215 | - |
dc.identifier.bibliographicCitation | KOREAN JOURNAL OF ANESTHESIOLOGY, Vol.47(2) : 211-215, 2004 | - |
dc.identifier.rimsid | 37454 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.