562 605

Cited 0 times in

Hydroxyapatite 피복 무시멘트 비구컵을 이용한 인공고관절 전치환술 -최소 10년 이상 추시 결과-

DC Field Value Language
dc.contributor.author양익환-
dc.contributor.author한창동-
dc.date.accessioned2015-06-10T12:56:50Z-
dc.date.available2015-06-10T12:56:50Z-
dc.date.issued2006-
dc.identifier.issn1226-2102-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/110734-
dc.description.abstractPurpose: We report on minimum 10-year follow-up results of total hip arthroplasties with hydroxyapatite (HA)-coated cementless acetabular cups. Materials and Methods: From January 1992 to October 1994, we performed one-hundred eight primary total hip replacements in ninety-seven patients using HA-coated cementless acetabular cup. Eighty-four cases in seventy-seven patients were followed-up for a minimum of 10 years. Results: The mean Harris score was 54.7 (range, 0 to 77.2) points preoperatively and 88.5 (range, 27.1 to 100) points at the most recent follow-up. Revision procedures were required on twenty-eight (33.3%) hips. Thirteen (15.5%) cups were revised because of loosening. Seven (9.5%) hips among the eight that revealed excessive polyethylene wear and osteolysis were revised and one hip is waiting for the revision procedure. In seven (8.3%) cases, only a polyethylene liner exchange was performed because of excessive liner wear without osteolysis. The mean linear polyethylene wear was 2.74 mm. The mean linear wear rate was 0.28 mm per year and the corresponding estimate of volumetric wear was 1689.15 ㎣, The mean linear polyethylene wear and linear wear rate in revised hips was 3.05 mm and 0.33 mm per year, respectively. The estimated volumetric wear in the revised group was 1882.27 ㎣. Conclusion: HA-coated cementless acetabular cup (Atoll®) demonstrated a high rate of loosening and poor results in wear and osteolysis. Further studies are needed to promote the design of acetabular cups and the technique of HA coating.-
dc.description.statementOfResponsibilityopen-
dc.format.extent761~769-
dc.relation.isPartOfJournal of the Korean Orthopaedic Association (대한정형외과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleHydroxyapatite 피복 무시멘트 비구컵을 이용한 인공고관절 전치환술 -최소 10년 이상 추시 결과--
dc.title.alternativeTotal Hip Arthroplasty with Hydroxyapatite-Coated Cementless Acetabular Cup - Minimum 10-Year Follow-up Result --
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Orthopedic Surgery (정형외과학)-
dc.contributor.googleauthor이동훈-
dc.contributor.googleauthor양익환-
dc.contributor.googleauthor한창동-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02313-
dc.contributor.localIdA04330-
dc.relation.journalcodeJ01839-
dc.subject.keywordHip joint-
dc.subject.keywordTotal hip arthroplasty-
dc.subject.keywordHydroxyapatite-
dc.subject.keywordAtoll acetabular cup-
dc.contributor.alternativeNameYang, Ick Hwan-
dc.contributor.alternativeNameHan, Chang Dong-
dc.contributor.affiliatedAuthorYang, Ick Hwan-
dc.contributor.affiliatedAuthorHan, Chang Dong-
dc.rights.accessRightsfree-
dc.citation.volume41-
dc.citation.number5-
dc.citation.startPage761-
dc.citation.endPage769-
dc.identifier.bibliographicCitationJournal of the Korean Orthopaedic Association (대한정형외과학회지), Vol.41(5) : 761-769, 2006-
dc.identifier.rimsid50184-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.