3 543

Cited 0 times in

Displacement of implant components from impressions to definitive casts

DC Field Value Language
dc.contributor.author김선재-
dc.contributor.author이근우-
dc.contributor.author한종현-
dc.date.accessioned2015-06-10T12:48:04Z-
dc.date.available2015-06-10T12:48:04Z-
dc.date.issued2006-
dc.identifier.issn0882-2786-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/110468-
dc.description.abstractPURPOSE: Four possible displacements of implant components from a patient model to a definitive cast were assessed to suggest a standard method of comparing the accuracies of implant impression techniques. MATERIALS AND METHODS: Two techniques for impression making were assessed: a nonsplinted open-tray technique and a light-curing resin splinted open-tray technique. A mandibular model with 5 parallel implants was fabricated. Five definitive casts were fabricated per technique. Using a computerized coordinate measuring machine, 5 part coordinate systems were established, and 7 sets of data were obtained for each sample. From the data, the amount of displacement while connecting components and the linear and angular displacement of components during impression making and cast fabrication were calculated. The Mann-Whitney test was used to determine significant differences between the impression techniques (P < .05). RESULTS: The average displacements while connecting impression copings and abutment replicas were 31.3 and 30.4 microm, respectively. Less displacement occurred in the nonsplinted group compared to the splinted group during impression making (P = .001) but greater displacement occurred in that group during definitive cast fabrication (P = .015). DISCUSSION: In contrast to previous studies, the current study excluded displacement resulting from component connection, because displacement from that source has no relation to impression technique and cannot be controlled. CONCLUSIONS: Connecting a component produced as great a displacement as that resulting solely from a impression or cast fabrication. The nonsplinted group was more accurate during impression making but less accurate during cast fabrication.-
dc.description.statementOfResponsibilityopen-
dc.format.extent747~755-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAcrylic Resins-
dc.subject.MESHDental Abutments*-
dc.subject.MESHDental Implantation, Endosseous-
dc.subject.MESHDental Implants*-
dc.subject.MESHDental Impression Technique/instrumentation*-
dc.subject.MESHDental Models*-
dc.subject.MESHDental Prosthesis Design*-
dc.subject.MESHHumans-
dc.subject.MESHMandible-
dc.subject.MESHSplints-
dc.subject.MESHStatistics, Nonparametric-
dc.titleDisplacement of implant components from impressions to definitive casts-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학)-
dc.contributor.googleauthorSunjai Kim-
dc.contributor.googleauthorJack I. Nicholls-
dc.contributor.googleauthorChong-Hyun Han-
dc.contributor.googleauthorKeun-Woo Lee-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00558-
dc.contributor.localIdA02688-
dc.contributor.localIdA04326-
dc.relation.journalcodeJ01142-
dc.identifier.eissn1942-4434-
dc.identifier.pmid17066636-
dc.identifier.urlhttp://www.quintpub.com/journals/omi/abstract.php?article_id=2449#.U6Jt5KizIyp-
dc.subject.keywordcoordinate measuring machine-
dc.subject.keyworddisplacement-
dc.subject.keywordimplant-
dc.subject.keywordimpression-
dc.contributor.alternativeNameKim, Sun Jai-
dc.contributor.alternativeNameLee, Keun Woo-
dc.contributor.alternativeNameHan, Jong Hyoun-
dc.contributor.affiliatedAuthorKim, Sun Jai-
dc.contributor.affiliatedAuthorLee, Keun Woo-
dc.contributor.affiliatedAuthorHan, Jong Hyoun-
dc.rights.accessRightsnot free-
dc.citation.volume21-
dc.citation.number5-
dc.citation.startPage747-
dc.citation.endPage755-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, Vol.21(5) : 747-755, 2006-
dc.identifier.rimsid39187-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.