309 615

Cited 0 times in

TDM검사 신빙도조사 결과보고 (2005)

DC Field Value Language
dc.contributor.author김정호-
dc.contributor.author임종백-
dc.date.accessioned2015-06-10T12:43:04Z-
dc.date.available2015-06-10T12:43:04Z-
dc.date.issued2006-
dc.identifier.issn1225-097X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/110320-
dc.description.abstractTwo trials of external quality assessment for Therapeutic Drug Monitoring (TDM) subcommittee of Korean Association of Quality Assurance for Clinical Pathology (KAQACP) were performed in 2005. The number of participating laboratories were increased to 95, by 6.7% increase comparing with the previous year. Response rates were 100.0% for both trials just like the two previous years. Two kinds of control materials were requested to be tested in each trial so that each institution could know the possible systematic error. In both trials, 20 test items were responded at least from one laboratory. The average drug item was 6.7 per institution, which was elevated slightly from 6.5 in recent 5 years. The most common test items were digoxin, valproic acid, carbamazepine, theophylline, phenytoin, and phenobarbital which were peformed in more than 65% of participating laboratories, followed by cyclosporine, lithium, vancomycin, tacrolimus, methotrexate, amikacin, gentamycin, tobramycin, salicylate, primidone, acetaminophen, free phenytoin, amitryptyline, and ethosuximide. The most widely used TDM analyzer was Abbott TDx/TDxFLx (41.7%), followed by Abbott AxSym (23.3%), and Roche Cobas Integra (19.2%). The inter-laboratory coefficients of variations were not much improved comparing with previous years. We also determined cyclosporine with reference method using liquid chromatography-tandem mass spectrometry. In conclusion, the TDM external quality assessment of 2004 showed grossly similar pattern comparing with those of previous year with increasing participating laboratories.-
dc.description.statementOfResponsibilityopen-
dc.format.extent121~134-
dc.relation.isPartOfJournal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleTDM검사 신빙도조사 결과보고 (2005)-
dc.title.alternativeAnnual Report on External Quality Assessment in Therapeutic Drug Monitoring in Korea (2005)-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthor김정호-
dc.contributor.googleauthor김병광-
dc.contributor.googleauthor이수연-
dc.contributor.googleauthor전사일-
dc.contributor.googleauthor권계철-
dc.contributor.googleauthor윤여민-
dc.contributor.googleauthor임종백-
dc.contributor.googleauthor신동훈-
dc.contributor.googleauthor송경은-
dc.contributor.googleauthor이경률-
dc.contributor.googleauthor서순팔-
dc.contributor.googleauthor김진규-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00903-
dc.contributor.localIdA03403-
dc.relation.journalcodeJ01555-
dc.subject.keywordQuality assurance-
dc.subject.keywordExternal quality assessment-
dc.subject.keywordTherapeutic drug monitoring-
dc.contributor.alternativeNameKim, Jeong Ho-
dc.contributor.alternativeNameLim, Jong Baeck-
dc.contributor.affiliatedAuthorKim, Jeong Ho-
dc.contributor.affiliatedAuthorLim, Jong Baeck-
dc.rights.accessRightsfree-
dc.citation.volume28-
dc.citation.number1-
dc.citation.startPage121-
dc.citation.endPage134-
dc.identifier.bibliographicCitationJournal of Laboratory Medicine and Quality Assurance (임상검사와 정도관리), Vol.28(1) : 121-134, 2006-
dc.identifier.rimsid38110-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.