306 814

Cited 0 times in

Peel-away® 유도자를 이용한 이중관 기관지튜브 삽관 경험

DC Field Value Language
dc.contributor.author남순호-
dc.date.accessioned2015-06-10T12:40:12Z-
dc.date.available2015-06-10T12:40:12Z-
dc.date.issued2006-
dc.identifier.issn1975-5171-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/110233-
dc.description.abstractIntubation of a double-lumen endotracheal tube (DLT) can be more difficult than a single-lumen endotracheal tube in difficult airways. Peel-away® introducer is used in urological procedures.A 54-year- old man undergoing right lung lobectomy could not be intubated with a 37Fr DLT through conventional laryngoscopy due to absences of upper incisors.We intubated a single-lumen tube through lightwand (TrachlightTM).And then the distal portion of Peel-away® introducer was first inserted to the single-lumen tube, and we extubated the single-lumen tube.We tried to intubate a DLT under guiding of Peel-away® introducer, Peel-away® introducer was easily passed through the DLT.After removing of Peel-away® introducer, the position of the DLT was corrected by fiberoptic bronchoscope.We experienced successful DLT intubation using Peel-away® introducer in a patient with absences of teeth.-
dc.description.statementOfResponsibilityopen-
dc.format.extent144~146-
dc.languageKorean-
dc.publisherKorean Society of Anesthesiologists-
dc.relation.isPartOfAnesthesia and Pain Medicine-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titlePeel-away® 유도자를 이용한 이중관 기관지튜브 삽관 경험-
dc.title.alternativeDouble-lumen Endotracheal Tube Insertion under Guiding of Peel-away® Introducer - ⁣ A case report ⁣--
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology (마취통증의학)-
dc.contributor.googleauthor반소영-
dc.contributor.googleauthor김민수-
dc.contributor.googleauthor금창만-
dc.contributor.googleauthor남순호-
dc.contributor.googleauthor류승훈-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01256-
dc.relation.journalcodeJ00145-
dc.identifier.eissn2383-7977-
dc.subject.keyworddouble-lumen-
dc.subject.keywordendotracheal tube-
dc.subject.keywordPeel-away ' Intro-ducer-
dc.contributor.alternativeNameNam, Soon Ho-
dc.contributor.affiliatedAuthorNam, Soon Ho-
dc.rights.accessRightsfree-
dc.citation.volume1-
dc.citation.number2-
dc.citation.startPage144-
dc.citation.endPage146-
dc.identifier.bibliographicCitationAnesthesia and Pain Medicine, Vol.1(2) : 144-146, 2006-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.